Toshiba TOSVERT VF-nC3 Instruction Manual page 179

Industrial inverter for 3-phase induction motors
Hide thumbs Also See for TOSVERT VF-nC3:
Table of Contents

Advertisement

7.2.2
Output terminal function (sink logic)
This function is used to output a variety of signals to external devices from the inverter.
With the contact output terminal function, you can select from multiple output terminal functions. Set two types of
functions for the OUT terminal and then you can output when either one or both of them is ON.
[Control terminal block]
OUT NO CC
Usage
FLA, B, C function: Set at parameter .
OUT-NO function: Set at parameter  and .
Assign one type of function to an output terminal
Terminal
Title
symbol
 Output terminal selection 1A
OUT-NO
FL
 Output terminal selection 2
(A, B, C)
Note) When assigning 1 type of function to the OUT-NO terminal, set only .
Leave parameter  as the standard setting ( = ).
FLA FLB FLC
CC VI
F
R
S1
Function
G-7
P5 FM
S2 P24
FLA
FLB
FL
FLC
OUT
NO
Adjustment range
Standard defaults
4 (Low-speed detection signal)
0 ∼ 255
E6581595
7
10 (fault FL)