[Selection 3: Setting vector control and manual tuning independently]
If an " " tuning error is displayed during auto-tuning or when vector control characteristics are to be
improved, set independent motor constants.
Title
Function
Slip frequency gain
Automatic torque boost value
Motor's rated capacity
Motor rated current
Motor no-load current
Motor rated rotational speed
Load moment of inertia ratio
Motor electronic thermal
protection level 1
*1: Depends upon the setup menu settings.
Adjustment range
0-150 (% )
0.0-30.0 (%)
0.01-5.50 (kW)
0.1-30.0 (A)
10-90 (%)
-1
100-32000 (min
)
0.1-100.0 (times)
10-100 (%) / (A)
F-39
E6581595
Default setting
50
Depends on
the capacity
(See 11.4)
*1
1.0
100
6