3.2.1
How to run and stop
[Example of a setting procedure]
Panel operation
LED display
MODE
⇔
(1) Run and stop using the panel keypad (=)
Use the
RUN
and
: Motor runs.
RUN
The direction of rotation is determined by the setting of parameter (forward run, reverse run
selection). (: forward run, : reverse run)
To switch between forward run and reverse run from the remote keypad (option), the parameter
(forward run, reverse run selection) needs to be set to or . (See 5.7 in E6581595.)
(2) RUN/STOP by means of an external signal to the terminal board (=):
Sink (Negative) logic
Use external signals to the inverter terminal board to start and stop the motor.
Short
and
F
CC
Open
and
F
CC
Displays the operation frequency (operation stopped).
(When standard monitor display selection = [Operation frequency])
Displays the first basic parameter [History ()].
Turn the setting dial, and select "".
Press the center of the setting dial to read the parameter value.
(Standard default: ).
Turn the setting dial to change the parameter value to (terminal
block).
Press the center of the setting dial to save the changed parameter.
and the parameter set value are displayed alternately.
STOP
keys on the panel keypad to start and stop the motor.
STOP
: Motor stops.
terminals: run forward
terminals: slow down and stop
C-5
Operation
Frequency
F-CC
E6581595
3
Slow down
and stop
ON
OFF