Toshiba TOSVERT VF-nC3 Instruction Manual page 50

Industrial inverter for 3-phase induction motors
Hide thumbs Also See for TOSVERT VF-nC3:
Table of Contents

Advertisement

3.2.1
How to run and stop
[Example of a  setting procedure]
Panel operation
LED display

MODE

⇔
(1) Run and stop using the panel keypad (=)
Use the
RUN
and
: Motor runs.
RUN
The direction of rotation is determined by the setting of parameter  (forward run, reverse run
selection). (: forward run, : reverse run)
To switch between forward run and reverse run from the remote keypad (option), the parameter 
(forward run, reverse run selection) needs to be set to  or . (See 5.7 in E6581595.)
(2) RUN/STOP by means of an external signal to the terminal board (=):
Sink (Negative) logic
Use external signals to the inverter terminal board to start and stop the motor.
Short
and
F
CC
Open
and
F
CC
Displays the operation frequency (operation stopped).

(When standard monitor display selection = [Operation frequency])
Displays the first basic parameter [History ()].
Turn the setting dial, and select "".
Press the center of the setting dial to read the parameter value.

(Standard default: ).
Turn the setting dial to change the parameter value to (terminal

block).
Press the center of the setting dial to save the changed parameter.
 and the parameter set value are displayed alternately.
STOP
keys on the panel keypad to start and stop the motor.
STOP
: Motor stops.
terminals: run forward
terminals: slow down and stop
C-5
Operation
Frequency
F-CC
E6581595
3
Slow down
and stop
ON
OFF

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents