Toshiba TOSVERT VF-nC3 Instruction Manual page 206

Industrial inverter for 3-phase induction motors
Hide thumbs Also See for TOSVERT VF-nC3:
Table of Contents

Advertisement

Communication
Title
No.

0005

0006

0008

0009

0010

0011

0012

0013

0014

0409

0015
11

0016

0600
*1: Depends upon the setup menu settings. See 11.5.
*2: Parameter values vary depending on the capacity. See 11.4.
Minimum
setting unit
Function
Unit
Panel/Commun
ication
Meter selection
-
Meter adjustment
-
gain
Forward/reverse
-
run selection
(Panel keypad)
Acceleration time
S
0.1/0.1
1
Deceleration time
S
0.1/0.1
1
Maximum
Hz
0.1/0.01
frequency
Upper limit
Hz
0.1/0.01
frequency
Lower limit
Hz
0.1/0.01
frequency
Base frequency 1
Hz
0.1/0.01
Base frequency
V
1/0.1
voltage 1
V/F control mode
-
selection
Torque boost
%
0.1/0.1
value 1
Motor electronic-
%
thermal protection
(A)
level 1
Adjustment range
-
0: Output frequency
1: Output current
2: Frequency reference
3: Input voltage (DC detection)
4: Output voltage (command value)
5 to 11: -
12: Frequency setting value (after
compensation)
13: VI input value
14: -
15: Fixed output 1
(output current 100% equivalent)
16: Fixed output 2
(output current 50% equivalent)
17: Fixed output 3
(Other than the output current)
18: RS-485 communications data
19: For adjustments ( set value is
displayed.)
20 to 22: -
-
-
-
0: Forward run
1: Reverse run
2: Forward run (F/R switching on
remote keypad)
3: Reverse run (F/R switching on
remote keypad)
0.0-3000
0.0-3000
30.0-400.0
0.5- 
0.0- 
20.0-400.0
50-330
-
0: V/F constant
1: Variable torque
2: Automatic torque boost control
3: Vector control
4: Energy-saving
0.0-30.0
1/1
10-100
K-2
E6581595
Default
User
Reference
setting
setting
0
3.4
-
0
5.7
10.0
5.3
10.0
*1
5.8
*1
5.9
0.0
5.10
*1
5.10
*1
6.12.5
0
5.11
* 2
5.12
100
3.5
6.16.1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents