Rfid Interface; Wiegand Interface; Received Code Format - 2N IP intercom Configuration Manual

Table of Contents

Advertisement

Associated switch – set the number of the switch to be activated by tapping of a
valid RFID card. The set value is not applied when a valid user card is tapped on
the reader while the double authentication mode is enabled. In this case, a
numeric switch activating code is required to identify the switch to be
activated.)
Read signalling – set one of the card reading signalling modes:
Full
– acoustic signals distinguish valid/invalid cards
Single beep
None
– acoustic signalling is disabled
Direction – set the reader direction (Not specified, Arrival, Departure) for the
Attendance system purposes.
Limit failed access attempts – the card reader is blocked (rejects all cards) for
thirty seconds after five unsuccessful access attempts.

RFID Interface

Allowed card types – select one or more card types to be accepted. If no
selection is made, all types of supported cards are accepted.

Wiegand Interface

Interface mode – enable the Wiegand function and set Wiegand IN/OUT. The IDs
of the cards tapped on the internal card reader are always resent to Wiegand
OUT.

Received code format

26, 32, 37 and RAW).
2N TELEKOMUNIKACE a.s., www.2n.cz
– one beep signals both valid and invalid cards
set the format for the codes to be received (Wiegand
101/198

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents