Exit Rules; Virtual Card To Wiegand; Silent Alarm Enabled; Limit Failed Access Attempts - 2N IP intercom Configuration Manual

Table of Contents

Advertisement

Virtual card to Wiegand – select a group of Wiegand outputs to which the
Virtual user card No. shall be sent after successful authentication. Can be
combined with any authentication method, including codes, fingerprints, etc.
Silent alarm enabled – a virtual code higher by 1 than the access code is assigned
to each access code and used for silent alarm activation. For example, if the
access code is 0000, then the silent alarm activation code is 0001. It means, for
instance, that silent alarm is 0000 for access code 9999 and so on. Set the silent
alarm action in the Automation section.
Limit failed access attempts – enable the maximum count of unsuccessful
authentication attempts. After five unsuccessful attempts (wrong numeric code,
invalid card, etc.), the access module will be blocked for 30 seconds even if
authentication is valid.
Plus card ID – enter the service card ID for adding cards to the Installed cards: a
sequence of 6 to 362 characters including 0–9, A–F.
Minus card ID – enter the service card ID for removing cards from the Installed
cards: a sequence of 6 to 32 characters including 0–9, A–F.

Exit Rules

Access enabled – enable access in a direction (entry, exit). If access is disabled,
the door cannot be opened from the selected side.
Door locking – display the active door lock setting: Unlocked/Locked.
2N TELEKOMUNIKACE a.s., www.2n.cz
62/198

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents