Advertisement

Quick Links

 
 
Installation manual 2N® IP
Uni
 
 
 
 
 
v.2.16
www.2n.com

Advertisement

Table of Contents
loading

Summary of Contents for 2N IP Uni

  • Page 1     Installation manual 2N® IP           v.2.16 www.2n.com...
  • Page 2: Table Of Contents

    Installation manual 2N® IP Uni Content: • 1. Product Overview • 1.1 Components and Associated Products • 1.2 Terms and Symbols • 2. Description and Installation • 2.1 Before You Start • 2.2 Mechanical Installation • 2.3 Electric Installation •...
  • Page 3: Product Overview

    ®  IP Uni is very easy to install. All you have to do is connect the system into your LAN via a network cable and feed it from a 12 V power supply or your PoE supporting LAN.
  • Page 4: Components And Associated Products

    Installation manual 2N® IP Uni 1.1 Components and Associated Products Basic Units • 1 button • control of one electric lock 2N Part No. 9153101 • protective switch Axis Part No. 01361-001 • 2 buttons • control of one electric lock 2N Part No. 9153102...
  • Page 5 Axis Part No. 01363-001 ® All 2N  IP Uni units can be flush mounted without requiring any additional accessories. Use the ® appropriate mounting box (see below) for wall (surface) mounting. 2N  IP Uni  is designed for outdoor applications and requires no additional roof.
  • Page 6 Installation manual 2N® IP Uni Mounting Accessories • Wall mounting box 2N Part No. 9153003 • (Al casting) Axis Part No. 01364-001 • Brick flush mounting box • (included in the delivery) 6 /  58...
  • Page 7 The elegant internal touch panel, 2N Indoor Touch 2N Part No. 91378375 2.0, is suitable for all 2N IP intercoms. On the panel’s Axis Part No. 01668-001 display not only can you find out who is at the door, but also start a conversation with the visitor, open the 2N Part No. 91378376...
  • Page 8 The elegant internal touch panel, 2N Indoor Touch 2N Part No. 91378375WH 2.0, is suitable for all 2N IP intercoms. On the panel’s Axis Part No. 01669-001 display not only can you find out who is at the door, but also start a conversation with the visitor, open the 2N Part No. 91378376WH...
  • Page 9 Installation manual 2N® IP Uni ® • Indoor Touch desk stand white 2N Part No. 91378382W Axis Part No. 01426-001 ® •  IP Handset • answering unit 2N Part No. Axis Part No. • white color 1120101W 02518-001 9 /  58...
  • Page 10 Installation manual 2N® IP Uni ® •  IP Handset • answering unit 2N Part No. Axis Part No. • black color 1120101B 02519-001   IP Phones • Yealink SIP T58A IP video phone  • simple operation 2N Part No. 91378360 •...
  • Page 11 Installation manual 2N® IP Uni 2N Part • Grandstream GXV3370 IP video phone No. 91378362EU • Android 7.0 OS • 7” touch display control • HD quality video calls • WiFi and Bluetooth support • Easy integration with IP intercoms, PBXs and security cameras.
  • Page 12 Installation manual 2N® IP Uni Part No. 11202102 • Mini electronic doorstrike series 5 – with momentum pin • electric opener designed for door frame installation • intended for such narrow profiles as aluminum, wood or PVC in particular •...
  • Page 13 Installation manual 2N® IP Uni Part No. 11202103-L • Mini electronic doorstrike series 5 – with mechanical blocking, long • electric opener designed for door frame installation • intended for such narrow profiles as aluminum, wood or PVC in particular •...
  • Page 14 Installation manual 2N® IP Uni Part No. 11202105 • Mini electronic doorstrike series 5 – fail-safe • electric opener designed for door frame installation • intended for such narrow profiles as aluminum, wood or PVC in particular • under voltage: opener secured, blocked •...
  • Page 15 Electromechanical lock SAM 7255 • 72/55 self-locking lock with panic function • A key is necessary for door opening from the outside (or an electric pulse from a connected 2N IP intercom / reader). • convenient solution for emergency exits Part No.
  • Page 16 Electromechanical lock SAM 9235 • 92/35 self-locking lock with panic function • A key is necessary for door opening from the outside (or an electric pulse from a connected 2N IP intercom / reader). • convenient solution for emergency exits Part No. 11202202-M •...
  • Page 17 Installation manual 2N® IP Uni Part No. 11202302 • Cable protector FX510 • Provides secure passage and protection of the supply cable between the door frame and the door leaf. • 510 mm length Part No. 11202303 • Cable protector FX300G •...
  • Page 18 Installation manual 2N® IP Uni Part No. 11202107 • Maglock MEX100 • used as a door holding supplement, not replacing the lock • consists of two parts: supplied part and counterpart • under voltage: door cannot be opened • at voltage interruption: magnets get disconnected, door opens Part No.
  • Page 19 Installation manual 2N® IP Uni  • FAQ: Electric locks – Difference between locks in 2N IP intercoms accesories Power Supply • PoE injetor – with EU cable • PoE injector – with US cable Part Numbers: • For power supply of intercom via ethernet cable 2N Part No.
  • Page 20 Installation manual 2N® IP Uni • 12 V transformer • For 230 V mains voltage. Part No. 932928 • For external power supply of the lock with 12 V AC voltage. Additional Modules ® •  Security Relay • A handy add-on that significantly enhances door entry 2N Part No. 9159010...
  • Page 21 Axis Part No. 01404-001 intercom to connect any IP device. You don’t have to ® configure anything, and you only need one 2N 2Wire unit at each end of the cable and a power source connected to at least one of these units.
  • Page 22 • Induction Loop • An induction loop transmits sound wirelessly from the 2N Part No. 9159050 2N IP intercom to the earphones of people with Axis Part No. 01391-001 hearing disabilities and enables them to hear and perceive sounds better. • Stabilised 12 V / 2 A power supply needs to be used when no PoE is available.
  • Page 23: Terms And Symbols

    Installation manual 2N® IP Uni  • For more accessories and particular advice please contact your local distributor of 2N products. 1.2 Terms and Symbols The following symbols and pictograms are used in the manual:  Safety • Always abide by this information to prevent persons from injury.
  • Page 24: Description And Installation

    • 2.4 Button Tags • 2.5 Extending Module Connection 2.1 Before You Start Product Completeness Check ® Before you start please check the contents of your 2N  IP Uni delivery: ® • 1x 2N  IP Uni • 1x Torx 10 / Torx 20 double-ended wrench •...
  • Page 25 Installation manual 2N® IP Uni  Caution ® • Stainless steel screws are used for the 2N IP Uni assembly. Other screws than stainless steel ones corrode soon and may aesthetically deteriorate the surrounding environment! • Having removed the front panel, make sure that no dirt gets inside the product (especially onto the sealing surface).
  • Page 26 Installation manual 2N® IP Uni  Caution • Before starting the mechanical installation on a selected place, make sure carefully that the preparations connected with it (drilling, wall cutting) cannot damage the electrical, gas, water and other existing wires and pipes.
  • Page 27 Installation manual 2N® IP Uni Mounting completion – after electric installation! Insert the intercom in the mounting box in the wall. Tighten the intercom with the stainless steel screws included in the delivery. As the screw holes are oval, you can perfect the vertical position before tightening.
  • Page 28 Installation manual 2N® IP Uni Hole dimensions for flush mounting Flush Mounting – Plasterboard What you need: • Just a properly cut hole 28 /  58...
  • Page 29 Installation manual 2N® IP Uni  • If this is your first plasterboard installation, check the function of the intercom side clamps. Loosen and then re-tighten the clamp screw to see how it turns automatically and starts moving forwards in its slot.
  • Page 30 What you need: • Wall mounting box Part No. 9153003 ® The 2N  IP Uni Al box, (Part No. 9153003) is designed for wall mounting especially where flush mounting is impossible such as on carrier elements of industrial objects. 30 /  58...
  • Page 31 Installation manual 2N® IP Uni Mounting instructions: a) If the cable wall outlets are located directly under the intercom to be installed, move the cap from the middle hole to the bottom one to make way for the cables. Make sure that no water can get into the intercom through the middle hole! The best solution is to...
  • Page 32: Electric Installation

    Installation manual 2N® IP Uni Dimension for wall (surface) mounting 2.3 Electric Installation ®  This subsection describes how to connect 2N IP Uni into your Local Area Network (LAN) and how to connect supply voltage and the electric lock.  Caution •...
  • Page 33 We recommend the use of a shielded SSTP Ethernet cable. External Power Supply Connection ®  IP Uni can be fed either from an external 12 V / 2 A DC power supply or from the LAN equipped with the PoE 802.3af supporting network elements. External Power Supply An external 12 V power supply is connected to terminal block POWER.
  • Page 34 Installation manual 2N® IP Uni  • Output wiring diagram for Relay terminals Wiring diagram for the controlled device’s electric circuit closing   Wiring diagram for the controlled device’s electric circuit opening 34 /  58...
  • Page 35 Installation manual 2N® IP Uni  Warning When you connect a device containing a coil, such as a relay or an electromagnetic lock, it is necessary to protect the intercom against voltage peak while switching off the induction load. For this way of protection we recommend a diode 1A / 1000V (e.g., 1N4007, 1N5407, 1N5408) connected antiparallel to the device.
  • Page 36 Tamper switch contacts are available on terminal block TAMPER SWITCH. Device Resetting ®  IP Uni is equipped with a RESET button. Push the button for 30 s to reset the factory default values, deleting all the data stored in the device.   Caution •...
  • Page 37: Overvoltage Protection

    2N device wiring may be exposed to atmospheric effects resulting in overvoltage that may subsequently damage any devices installed outside the building, on its outer wall or roof.
  • Page 38 Tag Printing ® Every 2N  IP Uni delivery includes a sheet of translucent foil, which can be laser-printed. Cut the printed foil and insert the tags in the name plates (template for printing is available in section Downloads). Every name plate includes a piece of foil, which can be written over manually, using a waterproof permanent marker, if necessary.
  • Page 39: Extending Module Connection

    Tag Inserting/Replacing Instructions ®  IP Uni provides an intuitive, easy access to the name plates. The tags are easy to insert and replace even without a manual. You need not remove the front panel and thus are not exposed to the risk of loss of components while replacing the tags.
  • Page 40 Installation manual 2N® IP Uni Specifications: Passive switch: NO and NC contacts, up to 30 V / 1 A AC/DC Switched output: • Where the security relay is fed from the intercom, 9 to 13 V DC is available on the output depending on the power supply (PoE: 9 V;...
  • Page 41 In case of resetting the factory default settings on a device with a version of firmware 2.18 or higher it is necessary to reprogram the ®  Security Relay using the instructions above.  ® • FAQ: Security Relay – what it is and how to use it with 2N IP intercom? 41 /  58...
  • Page 42 Induction Loop ®  Induction Loop (Part No. 9159050 – Induction loop amplifier for 2N IP intercom, Part No. 9159054 – Induction loop amplifier without 2N IP intercom accessory, Part No. 9159052 – 12 V DC power adapter) is part of sound system installations for hearing impaired persons that are equipped with a special hearing aid capable of receiving reproduced sound via a magnetic field receiver.
  • Page 43 You can place the mated A and B connectors into the 2N IP intercom cover. The connectors help you connect stripped cables. Open the connector by pushing a thin screwdriver onto the white spots at its front and close the connector by sliding the movable part through a side gap.
  • Page 44 Installation manual 2N® IP Uni • no signal; 100 mA • standby; up to 10 mA • Transition to standby w/o signal: 10 s • Input level – basic: 100 mV – 6 V • Input level – increased: 1 V – 35 V •...
  • Page 45: Function And Use

    You have to know the IP address of your device to log in to the integrated web server. By ® default, 2N  IP Uni is switched into the dynamic IP address mode, i.e. it obtains the IP address automatically if a properly set DHCP server is available in your LAN. If no such DHCP server is ®...
  • Page 46 Installation manual 2N® IP Uni IP Address Retrieval ® Take the following steps to retrieve the 2N  IP Uni IP address: ® • Connect (or, if connected, disconnect and reconnect) 2N  IP Uni to the power supply. • Wait for the second sound signal  •...
  • Page 47 Installation manual 2N® IP Uni Static/Dynamic Address Setting Mode Switching ® In case your 2N  IP Uni device is equipped with 1 or 2 buttons, you can switch the modes using one button only. ® • Connect 2N  IP Uni to the power supply (or, disconnect and reconnect it if already connected).
  • Page 48: Control

    3.2 Control ® This subsection describes how to control 2N  IP Uni when viewed by an external user. Speed Dial Buttons Press the speed dial buttons on the basic unit to make quick dialling for the first 1 or 2 (depending on the model type) in the telephone directory. Call setup is signalled by a long intermittent tone or otherwise as configured in the PBX connected.
  • Page 49: Downloads

    The manufacturer reserves the right to modify the product in order to improve its qualities. ® • IP Uni contains no environmentally harmful components. When the product's service life is exhausted and you would like to dispose of it please do so in accordance with applicable legal regulations. 3.4 Downloads...
  • Page 50: Technical Parameters

    Installation manual 2N® IP Uni 4. Technical Parameters Signalling protocol • SIP (UDP, TCP) Buttons • Button design: Transparent, white backlit buttons with easily replaceable name tags • Button count: 1 or 2 Audio • Microphone: 1 integrated microphone • Amplifier: 1 W (class D) •...
  • Page 51 Installation manual 2N® IP Uni Interfaces • Power supply: 12 V ± 15 % / 2 A DC or PoE • PoE: PoE 802.3af (Class 0 – 12.95 W) • LAN: 10/100BASE-TX s Auto-MDIX, RJ-45 • Recommended cabling: Cat-5e or higher • Passive switch: NO and NC contacts, up to 30 V / 1 A AC/DC •...
  • Page 52: General Drawings

    Installation manual 2N® IP Uni 4.1 General drawings Surface mounting Flush mounting Plasterboard mounting Flush mounting with box 52 /  58...
  • Page 53: Supplementary Information

    5.1 Troubleshooting For the most frequently asked questions refer to faq.2n.cz. 5.2 Directives, Laws and Regulations ® <span class="productName">IP Uni</span> conforms to the following directives and regulations: • 2014/35/EU for electrical equipment designed for use within certain voltage limits •...
  • Page 54 Installation manual 2N® IP Uni • Consult the dealer or an experienced radio/TV technician for help Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment.
  • Page 55: General Instructions And Cautions

    / device in contradiction to the manufacturer’s instructions, guidelines or recommendations or in conjunction with unsuitable products / devices of other suppliers, the customer agrees that the 2N TELEKOMUNIKACE a.s. company shall not be held liable for any functionality limitation of such a product or any damage, loss or injury related to this potential functionality limitation.
  • Page 56 Installation manual 2N® IP Uni Moreover, the manufacturer shall not be liable for any damage or destruction of the product incurred as a result of misplacement, incompetent installation and/or undue operation and use of the product in contradiction herewith. The manufacturer assumes no responsibility for any malfunction, damage or destruction of the product caused by incompetent replacement of parts or due to the use of reproduction parts or components.
  • Page 57 Installation manual 2N® IP Uni friendly disposal. The dealer or manufacturer shall take the product back free of charge and without requiring another purchase. Make sure that the devices to be disposed of are complete. Do not throw battery packs into fire. Battery packs may not be taken into parts or short-circuited either.
  • Page 58 Installation manual 2N® IP Uni 58 /  58...

This manual is also suitable for:

915310191531029153101p

Table of Contents