General - Tait TB8100 User Manual

Service kit
Hide thumbs Also See for TB8100:
Table of Contents

Advertisement

Profile name
Receiver channel
96 Part F: Configuring Channels

General

The General tab in the Add or Edit Channel Profile dialog box names the
channel profile and defines its general characteristics.
Specifies the name of the profile. You can edit the name of custom profiles.
RF Configuration
In the Add or Edit Channel Profile dialog, General tab, the RF configuration
area lets you specify the nominal channel spacing for the receiver and the
transmitter. No hardware modification is necessary when the RF configuration
is changed.
Your country may use Narrow band, Mid band and Wide
Note:
band to refer to different channel spacings. Make sure that the
option you select has the correct value.
Specifies the receiver's nominal channel spacing. The available options are
expressed both as a description (for example, Mid Band) and as the kHz value
of the nominal channel spacing.
Option
12.5 kHz Narrow Band
20 kHz Mid Band
25 kHz Wide Band
Note:
The Receiver channel box does not determine the actual
spacing between channels. It determines the receiver IF bandwidth.
For example, 20 kHz Mid Band sets the receiver IF bandwidth to
12 kHz. Normally, you would select this option if the channels in your band
plan have a 20 kHz channel spacing. However, your band plan may be
irregular, or you may want to specify (in the channel table) a greater spacing
between channels, for example, 50 kHz.
Equivalent Rx IF Bandwidth
7.5 kHz
12 kHz
15 kHz
MB8100-00-00-806 © TEL 2003