Altering Alarm Thresholds

Minimum PA
power output
Maximum PA
reverse power
output
Maximum PA
VSWR
TB8100 Service Kit User's Manual
The Thresholds form (Configure > Alarms > Thresholds) lets you alter the
thresholds for base station alarms.
Some alarm thresholds are fixed; they are built in to the base station and cannot
be changed. Others have default values. You may want to adjust them to better
reflect your system's operating conditions or monitoring procedures. This can
be important if an alarm is used as an input in Task Manager tasks.
The form displays a list of upper and lower limits. Alongside each threshold is
the applicable unit. To the right, a box displays the current value of the relevant
parameter. When a parameter value goes outside its limit, the base station
triggers the corresponding alarm.
To adjust a threshold, edit its value or click one of the adjacent arrows, and then
click OK to confirm your changes and close the form.
The alarms that these thresholds apply to are described in
on page
127. The equivalent Task Manager inputs are described in
Inputs" on page
180.
Defines the lower limit for the PA forward power output. When the output
falls below this limit, the base station triggers the alarm
the Task Manager input
Defines the upper limit for the PA's reverse power. When the reverse power
exceeds this limit, the base station triggers the alarm
the Task Manager input
Defines the upper limit for the VSWR. When the VSWR exceeds this limit,
the base station triggers the alarm
VSWR fault
becomes true.
Forward power low
becomes true.
Reverse power high
becomes true.
VSWR high
and the Task Manager input
"Monitoring Alarms"
"Alarm
Forward power low
and
Reverse power high
and
Altering Alarm Thresholds 137