Testing The Pmu Fault Led - Tait TB8100 User Manual

Service kit
Hide thumbs Also See for TB8100:
Table of Contents

Advertisement

TB8100 Service Kit User's Manual
Test the fan after fixing a fan problem or fitting a new fan. When you fit a fan,
use this test to verify that the fan is correctly connected, so that the PA and not
the PMU activates it.
The base station can detect the motion of 3-wire fans and will
Note:
raise an alarm if the fan does not operate.
To test the fan
1. Select Diagnose > Power Management > Control Tests.
1. Click Toggle to the left of the PMU fan LED. If the fan was off, this should
turn it on.
2. Check that the fan is operating.
After ten seconds, the test automatically ends and the base station takes back
control of the fan.

Testing the PMU fault LED

You can test that the fault LED on the front of the PMU is able to light up.
(This LED is only visible when the front panel is removed.)
1. Select Diagnose > Power Management > Control Tests.
2. Click Start Test to the left of the PMU fault LED. This uncouples the LED
from the PMU's operational logic.
3. Check that the PMU LED flashes on and off. (The control panel LED
should also light up, unless all PMU alarms are disabled.)
4. Click Stop Test to restore the LED's connection with the PMU.
Testing the Auxiliary Power Output
If the PMU is fitted with an auxiliary power supply submodule, you can test
the PMU's ability to switch its output on and off.
The auxiliary power output must be on. If it is configured to
Note:
be on only when the PMU uses mains power, make sure that the
PMU is not using battery power.
1. Select Diagnose > Power Management > Control Tests.
2. Click Start Test at the bottom of the form.
3. Click the Toggle button above the Aux Output box.
The state of the LED should change.
4. Click Stop Test.
Power Management Unit Tests 165