156 Part H: Diagnosing

Testing Digital Outputs

You can toggle any digital output line or the Rx Gate output line between
active
and inactive. Use this test to make sure that the output is working and
to check that any equipment attached to that output responds as intended.
To test a digital output
1. Select Diagnose > Reciter > Digital I/O.
2. Click Start Test. This enables the Toggle buttons in the Digital Outputs
area. This area now displays the output states as they were when you started
the test.
3. Click the digital output's (or Rx Gate's) Toggle button to change its state.
When the output is activated, its LED displays Green. (If the output is not
present on the system interface board, an error message appears.)
4. Check the response of any attached equipment.
When you have finished testing the outputs, click Stop Test. This returns all
digital outputs to the state they were in when you started the test.
Testing Digital Inputs
The Digital inputs area displays the current state of all digital inputs to the
reciter.
MB8100-00-00-806 © TEL 2003