Ex Relevant Specifications - ABB FV4000 Operating Instruction

Vortex/swirl flowmeter
Table of Contents

Advertisement

Ex relevant specifications

11 Ex relevant specifications
11.1 General ex relevant specifications
11.1.1 HART devices
Models designed for hazardous areas with ATEX / IECEx approval
Models
VT41 / ST41 / VR41 / SR41
Important
All types of protection are noted on the name plate.
Flowmeters operating in Category 3 (Zone 2 / 22) may subsequently be operated in Category
2 (Zone 1 / 21) without modification.
The respective applicable maximum values must be complied with.
Models
VT42 / ST42 / VR42 / SR42
Important
All types of protection are noted on the name plate. In the case of operation in Zone 1, the
user specifies the type of protection by means of the type of supply.
Flowmeters operated in Category 3 (Zone 2) may subsequently be operated in Category 2
(Zone 1) without modification. Within Category 2, the Ex d [ib] design may subsequently be
operated as EX ib without modification.
The respective applicable maximum values must be complied with. The significant differences
between models are listed in the table titled "Differences between explosion-proof designs with
regard to safety engineering". Detailed descriptions appear later in this section.
96
Approvals
Operation in Zone 1:
Ex ib IIC (intrinsically safe supply)
Operation in Zone 2:
Ex nA [nL] IIC (non-intrinsically safe supply)
Operation in Zone 21 / 22:
Ex tD A21 / Ex tD A22 (non-intrinsically safe supply or
intrinsically safe supply)
Approvals
Operation in Zone 1:
Ex d [ib] IIC (non-intrinsically safe supply)
Operation in Zone 1:
Ex ib IIC (intrinsically safe supply)
Operation in Zone 2:
Ex nA [nL] IIC (non-intrinsically safe supply)
Operation in Zone 21 / 22:
Ex tD A21 / Ex tD A22 (non-intrinsically safe supply or
intrinsically safe supply)