Alarm Output - Dahua HCVR5104C User Manual

Hdcvi standalone dvr. hcvr5104c series; hcvr51xxc-v2 series; hcvr7104c-v2 series; hcvr410xc-s2 series; hcvr510xc-s2 series; hcvr7104c-s2 series; hcvr2108c-s2 series; hcvr410xc-s3 series; hcvr510xc-s3 series; hcvr7104c-s3 series; hcvr51xxh serie
Hide thumbs Also See for HCVR5104C:
Table of Contents

Advertisement

Parameter
Function
Event Type
The abnormal events include: No disk, disk error, disk no space, net
disconnection, IP conflict and MAC conflict.
You can set one or more items here.
Less than: You can set the minimum percentage value here (For disk
not space only). The device can alarm when capacity is not sufficient.
You need to draw a circle to enable this function.
Enable
Check the box here to enable selected function.
Alarm Out
Please select corresponding alarm output channel when an alarm
occurs. You need to check the box to enable this function.
The alarm output can delay for the specified time after an alarm stops. The
Latch
value ranges from 0s to 300s. The default setup is 10 seconds. The o
second means there is no delaying time.
It is to set login attempt times. Once the login attempt exceeds the
Attempt(s)
threshold you set here, current account will be locked. This function is
for illegal login only.
It is to set account lock time once its login attempt has exceeded the
Lock time
threshold you set. This function is for illegal login only.
High
In Device interface (Figure 5- 97), select High temperature from the
temperature
dropdown list, and then input the max temperature. The value ranges
from 30 ℃ ~ 90 ℃ . Device can trigger an alarm once the case
temperature is higher than the value you set.
Fan speed
In Device interface (Figure 5- 97), select Fan speed abnormal from the
abnormal
dropdown list, and then click the OK button after the Fan calibration. It
can correct fan manually. Please note we recommend this function after
you replaced or maintained the fan.
Show
System can pop up a message to alarm you in the local host screen if
message
you enabled this function.
Alarm
System can upload the alarm signal to the center (Including alarm
upload
center.
Send Email
If you enabled this function, System can send out an email to alert you
when an alarm occurs.
Buzzer
Check the box here to enable this function. The buzzer beeps when an
alarm occurs.
Log
Check the box here, system can record the network event alarm log.

5.10.3.6 Alarm Output

5.10.3.6.1 General Alarm
It is to set alarm output mode. See Figure 5- 98.
565

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hcvr5108c-v2Hcvr7104c-v2Hcvr4108c-s2Hcvr5104c-v2Hcvr5104c-s2Hcvr4104c-s2 ... Show all

Table of Contents