Message
Slot <value> PoE power usage exceed threshold limit
Severity
INFO
Description
This message is generated when the PoE card consumed more power than the
threshold set.
Synopsis
N/A
Action
Monitor the overall power consumption to prevent PoE power overload. If
necessary, disable PoE port power administratively.
Message
Slot <value> PoE power usage returns below threshold limit
Severity
ERROR
Description
This message is generated when the PoE card consumes less power than the
threshold set after exceeding it.
Synopsis
N/A
Action
N/A
Message
Slot <value>: <msg>
Severity
INFO
Description
This message is generated when the system receives boot time information from
a different slot.
Synopsis
N/A
Action
N/A
Message
Slot <value> cardPN is not programmed
Severity
ERROR
Description
This message is generated when the card part number is missing in SEEPROM.
Synopsis
N/A
Action
Replace the card.
Message
slot <value> has no PartNumber in SEEPROM.,
Severity
WARNING
Description
This message is generated when the part number is missing in SEEPROM.
Synopsis
N/A
Action
Replace card.