Nortel 8300 Reference Manual page 104

Ethernet routing switch system messaging platform
Hide thumbs Also See for 8300:
Table of Contents

Advertisement

104 Chapter 4 SMP log error messages
Message
Invalid Card Type fpr phyInit Slot <value>
Severity
WARNING
Description
This message indicates that an invalid card type has been detected.
Synopsis
N/A
Action
N/A
Message
Invalid configuration: network appears in two areas
Severity
INFO
Description
This message is generated when the same route appears for different areas.
Synopsis
Two areas have the same network.
Action
Configure the network properly so there is no repetition.
Message
invalid interface index
Severity
ERROR
Description
This message is generated when a VLAN ID is out of range. For example, if you
enable or disable IGMP for the circuit using an invalid VLAN, then this error
message occurs.
Synopsis
The VLAN interface being used is invalid.
Action
Provide a valid VLAN ID. Check the instructions in the VLAN configuration
command. If this error persists, then contact customer support for further
information.
Message
Invalid Port <value>
Severity
ERROR
Description
This message indicates that port translation failed.
Synopsis
N/A
Action
N/A
Message
invalid power supply configuration detected, PoE disabled and all PoE power
removed
Severity
ERROR
Description
This message indicates that mixed types of power supplies were installed in the
chassis.
Synopsis
PoE function disabled.
Action
Remove or replace power supplies to ensure that there are no mixed types of
power supplies installed.
316806-C

Advertisement

Table of Contents
loading