ANY KIND, EITHER EXPRESS OR IMPLIED. The information and/or products described in this document are subject to change without notice. Nortel, the Nortel logo, the Globemark, and Passport are trademarks of Nortel Networks. All other trademarks are the property of their respective owners.
Page 4
Mounting the Ethernet Routing Switch 8310 and 8306 chassis in an equipment rack 36 Procedure job aid: Maximum number of chassis installed in 7-foot rack 40 Installing the cable guides 40 Switch operations Powering on DC power supplies 43 Powering on AC power supplies 44...
EN 55 024 (CISPR 24). EN 300386 Statement The Ethernet Routing Switch 8300 Series chassis complies with the requirements of EN 300386 V1.3.3 for emissions and for immunity for a Class A device intended for use in either Telecommunications centre or locations other than telecommunications centres given the performance criteria as specified by the manufacturer.
Page 9
Norma Oficial Méxicana (NOM): Exportador: Nortel Networks, Inc. 4655 Great America Parkway Santa Clara, CA 95054 USA Importador: Nortel Networks de México, S.A. de C.V. Avenida Insurgentes Sur #1605 Piso 30, Oficina Col. San Jose Insurgentes Deleg-Benito Juarez México D.F. 03900...
30 days of purchase to obtain a credit for the full purchase price. "Software" is owned or licensed by Nortel Networks, its parent or one of its subsidiaries or affiliates, and is copyrighted and licensed, not sold. Software consists of machine-readable instructions, its components, data, audio-visual content (such as images, text, recordings or pictures) and related licensed materials including all whole or partial copies.
Page 16
Upon termination or breach of the license by Customer or in the event designated hardware or CFE is no longer in use, Customer will promptly return the Software to Nortel Networks or certify its destruction. Nortel Networks may audit by remote polling or other reasonable means to determine Customer’s Software activation or usage levels.
Page 17
Customer fails to comply with the terms and conditions of this license. In either event, upon termination, Customer must either return the Software to Nortel Networks or certify its destruction. Customer is responsible for payment of any taxes, including personal property taxes, resulting from Customer’s use of the Software.
New in this release The following sections detail what’s new in Nortel Ethernet Routing Switch 8300 Installation — Chassis Installation and Maintenance, NN46200-309 for Release 4.1: • “Features” (page 19) • “Other changes” (page 19) Features See the following sections for information about feature changes: •...
Nortel Ethernet Routing Switch 8300 modules. This document provides the instructions for installing the Nortel Ethernet Routing Switch 8300 chassis (8306 and 8310 chassis) in an equipment rack. This document also describes some of the routine tasks that you use to operate the Nortel Ethernet Routing Switch 8300 and includes technical specifications for the chassis and modules.
Chassis installation fundamentals This chapter describes fundamental information that you need for installing the Ethernet Routing Switch 8300 chassis (8306 and 8310 chassis) . Each Ethernet Routing Switch 8300 chassis consists of a sheet metal enclosure and a backplane. The number of bays for fan trays depends on the chassis type.
Page 24
24 Chassis installation fundamentals modules. Slots are numbered from the top down. You can install 8300 Series I/O switch modules in slots 1 through 4 and slots 7 through 10. Slots 5 and 6 are reserved for the 8393SF/CPU or 8394SF/CPU modules.
I/O modules and two slots for installing Ethernet Routing Switch 8393SF/CPU or 8394SF/CPU modules. See components" (page switch modules. Slots 5 and 6 are reserved for Ethernet Routing Switch 8393SF/CPU or 8394SF/CPU modules. The Ethernet Routing Switch 8306 chassis has three bays for either AC or DC power supplies and a single fan tray for cooling.
Figure 2 8306 chassis and components Power supplies The Ethernet Routing Switch 8306 and 8310 chassis each provide three bays for either AC or DC power supplies. The Ethernet Routing Switch 8306 and 8310 chassis supports the following AC power supplies: •...
Ethernet Routing Switch 8348GTX-PWR module Fan trays Table 1 "Number of fan trays installed for each chassis" (page 27) the number of fan trays for the Ethernet Routing Switch 8310 and 8306 chassis. Table 1 Number of fan trays installed for each chassis...
This section includes information about the hardware shipped with the 8306 and 8310 chassis. Shipment contents In addition to the Ethernet Routing Switch 8310 or 8306 chassis, your shipping container contains several hardware accessories. Verify that the items in the shipping container match those on the shipment packing list.
Page 31
Items in the Ethernet Routing Switch 8306 chassis shipping container Other equipment In addition to the items that are included in the Ethernet Routing Switch 8310 and 8306 chassis accessory package you must also supply other items. Before you install the hardware, ensure that you have all the cables, tools, and other equipment that you need.
Mounting hardware for the 8310, 8306 chassis To install the Ethernet Routing Switch 8310 or 8306 chassis in an equipment rack, you require a Phillips screwdriver and an equipment rack that meets the following specifications: •...
Ethernet Routing Switch 8310 and 8306 chassis installation This section describes how to install the Ethernet Routing Switch 8310 and 8306 chassis. Prerequisites • Inspect all items for shipping damage. If you detect damage, do not install the chassis. Call the Nortel Technical Solutions Center in your area.
Installation — Fan Tray, NN46200-302. Installing the chassis on a flat surface Mount the Ethernet Routing Switch 8310 and 8306 chassis on any flat, level surface, such as a tabletop or shelf, that can safely support the weight of the chassis, its components, and its attached cables to provide a convenient location for the safe operation of the switch.
Mounting the Ethernet Routing Switch 8310 and 8306 chassis in an equipment rack Install the Ethernet Routing Switch 8310 and 8306 chassis in a standard 19-inch equipment rack to provide a convenient location for the safe operation of the switch.
Mounting the Ethernet Routing Switch 8310 and 8306 chassis in an equipment rack 37 Prerequisites • To mount the chassis in an equipment rack, you need the following equipment: — standard 19 in. (48.2 cm) equipment rack — two rack mounting brackets —...
Page 39
Mounting the Ethernet Routing Switch 8310 and 8306 chassis in an equipment rack 39 Chassis 8310 8306 Holding the chassis in position, align the flanged end of each mounting rail with two holes on each side of the vertical rack support.
“Removing removable flash memory cards” (page 47) • “Protecting memory card files” (page 48) Powering on DC power supplies Power on the DC power supplies to provide power to the switch. Prerequisites • Ensure that the power supply is seated properly.
AC power outlets. Procedure steps Step Action On each AC power supply, turn the power switch to the on position. ATTENTION When you first install a chassis that contains two or three power supplies, you must turn on two of the power supply units simultaneously.
Ethernet Routing Switch 8394SF/CPU module. Figure 6 Reset button on the 8394SF/CPU module Installing removable flash memory cards Install a removable flash memory card in an Ethernet Routing Switch 8393SF/CPU module to provide alternative storage media. Procedure steps Step...
Gently push the card in until it fits snugly in place. Removing removable flash memory cards Remove a removable flash memory card from the Ethernet Routing Switch 8393SF/CPU or 8394SF/CPU module to stop using it as a storage medium. Procedure steps...
Write-protect the memory card for backup purposes after you successfully load the configuration file and save your configuration because Nortel ships each memory card with the read-write protect switch in the unprotected position. Typically, you do not operate the switch with a write-protected memory card.
Part Numbers This chapter provides a list of Nortel Ethernet Routing Switch 8300 hardware and part numbers. The following table lists Ethernet Routing Switch 8300 hardware and part numbers. Table 4 Ethernet Routing Switch 8300 hardware part numbers Part number...
Technical specifications This chapter lists the physical, environmental, and electrical specifications for the Ethernet Routing Switch 8310 and 8306 chassis and the available power supplies. Navigation • “Ethernet Routing Switch 8310 chassis specifications” (page 55) • “Ethernet Routing Switch 8306 chassis specifications” (page 57) •...
Page 68
NORTEL PROVIDES THIS DOCUMENT "AS IS" WITHOUT WARRANTY OR CONDITION OF ANY KIND, EITHER EXPRESS OR IMPLIED. The information and/or products described in this document are subject to change without notice. Nortel, the Nortel logo, the Globemark, and Passport are trademarks of Nortel Networks. All other trademarks are the property of their respective owners.