Nortel 8300 Reference Manual page 133

Ethernet routing switch system messaging platform
Hide thumbs Also See for 8300:
Table of Contents

Advertisement

Message
poePowerMgr: Could not start poePowerMgr task
Severity
ERROR
Description
This message indicates that the system was unable to execute the PoE task, so
PoE operation stopped.
Synopsis
N/A
Action
Reboot the switch.
Message
poePowerSourceScan: re-scan power profile
Severity
ERROR
Description
This message indicates a PoE power supply configuration error has been
detected.
Synopsis
N/A
Action
Re-scan the power supply and rebuild the PoE power profile.
Message
poeTask: PoE controller communication ERROR PoE is disabled
Severity
ERROR
Description
This message indicates that PoE controller initialization and communication
failed.
Synopsis
N/A
Action
Reset the PoE card using admin disable and then re-enable the card.
Message
poeTask: PoE local DB init ERROR PoE is disabled
Severity
ERROR
Description
This message indicates that PoE local configuration database initialization failed.
Synopsis
N/A
Action
Reset the PoE card using admin disable and then re-enable the card.
Message
poeTask: PoE module init ERROR PoE is disabled
Severity
ERROR
Description
This message indicates that PoE operational configuration initialization failed.
Synopsis
N/A
Action
Reset the PoE card using admin disable and then re-enable the card.