ABB ACS355 series User Manual page 95

Hide thumbs Also See for ACS355 series:
Table of Contents

Advertisement

How to select the monitored signals
Step Action
1.
You can select which signals are monitored in the Output
mode and how they are displayed with group
DISPLAY
parameters. See page
instructions on changing parameter values.
By default, the display shows three signals.
Signal 1:
0102 SPEED
Motor potentiometer, Hand/Auto and PID control;
0103 OUTPUT FREQ
Torque control
Signal 2:
0104 CURRENT
Signal 3:
0105
To change the default signals, select up to three signals
from group
01 OPERATING DATA
Signal 1: Change the value of parameter
PARAM
to the index of the signal parameter in group
OPERATING DATA
the leading zero), eg, 105 means parameter
TORQUE. Value 0 means that no signal is displayed.
Repeat for signals 2
(3415 SIGNAL3
2.
Select how you want the signals to be displayed: as a
decimal number or a bar graph. For decimal numbers,
you can specify the decimal point location, or use the
decimal point location and unit of the source signal
(setting 9 [DIRECT]). For details, see parameter 3404.
Signal 1: parameter
Signal 2: parameter
Signal 3: parameter
3.
Select the units to be displayed for the signals. This has
no effect if parameter
(DIRECT). For details, see parameter 3405.
Signal 1: parameter
Signal 2: parameter
Signal 3: parameter
4.
Select the scalings for the signals by specifying the
minimum and maximum display values. This has no
effect if parameter
For details, see parameters
Signal 1: parameters
OUTPUT1 MAX
Signal 2: parameters
OUTPUT2 MAX
Signal 3: parameters
OUTPUT3
MAX.
94
for macros 3-wire, Alternate,
for macros ABB standard and
TORQUE.
to be shown.
(= number of the parameter without
(3408 SIGNAL2
PARAM).
3404 OUTPUT1 DSP FORM
3411 OUTPUT2 DSP FORM
3418 OUTPUT3 DSP
3404/3411/3418
3405 OUTPUT1 UNIT
3412 OUTPUT2 UNIT
3419 OUTPUT3
3404/3411/3418
is set to 9 (DIRECT).
3406
and 3407.
3406 OUTPUT1 MIN
3413 OUTPUT2 MIN
3420 OUTPUT3 MIN
34 PANEL
for detailed
3401 SIGNAL1
01
0105
PARAM) and 3
FORM.
is set to 9
UNIT.
and
3407
and
3414
and
3421
Control panels 95
Display
LOC
PAR EDIT
3401 SIGNAL1 PARAM
OUTPUT FREQ
[103]
CANCEL
00:00
SAVE
LOC
PAR EDIT
3408 SIGNAL2 PARAM
CURRENT
[104]
00:00
CANCEL
SAVE
LOC
PAR EDIT
3415 SIGNAL3 PARAM
TORQUE
[105]
00:00
CANCEL
SAVE
LOC
PAR EDIT
3404 OUTPUT1 DSP FORM
DIRECT
[9]
CANCEL
00:00
SAVE
LOC
PAR EDIT
3405 OUTPUT1 UNIT
Hz
[3]
CANCEL
00:00
SAVE
LOC
PAR EDIT
3406 OUTPUT1 MIN
0.0 Hz
00:00
SAVE
CANCEL
LOC
PAR EDIT
3407 OUTPUT1 MAX
500.0 Hz
CANCEL
00:00
SAVE

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents