ABB ACS355 series User Manual page 297

Hide thumbs Also See for ACS355 series:
Table of Contents

Advertisement

All parameters
No.
Name/Value
SUPRV3
UNDER
TIMED FUNC 1 Logic value 1 is activated by timed function 1. See
TIMED FUNC 2 See selection
TIMED FUNC 3 See selection
TIMED FUNC 4 See selection
8407 SEQ LOGIC
OPER 1
NOT SEL
AND
OR
XOR
8408 SEQ LOGIC
VAL 2
8409 SEQ LOGIC
OPER 2
NOT SEL
AND
OR
XOR
8410 SEQ LOGIC
VAL 3
8411 SEQ VAL 1
HIGH
0.0...100.0%
8412 SEQ VAL 1
LOW
0.0...100.0%
8413 SEQ VAL 2
HIGH
0.0...100.0%
Description
See selection
SUPRV3
parameter group
36 TIMED
function active.
TIMED FUNC
TIMED FUNC
TIMED FUNC
Selects the operation between logic value 1 and 2. Logic
operation values are used in state transitions. See
parameter
8425 ST1 TRIG TO ST 2
ST N
selection
LOGIC
Logic value 1 (no logic comparison)
Logic function: AND
Logic function: OR
Logic function: XOR
See parameter
8406 SEQ LOGIC VAL
See parameter 8406.
Selects the operation between logic value 3 and the result
of the first logic operation defined by parameter
LOGIC OPER
1.
Logic value 2 (no logic comparison)
Logic function: AND
Logic function: OR
Logic function: XOR
See parameter
8406 SEQ LOGIC VAL
See parameter 8406.
Defines the high limit for the state change when parameter
8425 ST1 TRIG TO ST 2
Value as a percentage
Defines the low limit for the state change when parameter
8425 ST1 TRIG TO ST 2
Value as a percentage
Defines the high limit for the state change when parameter
8425 ST1 TRIG TO ST 2
Value as a percentage
Actual signals and parameters 297
OVER.
FUNCTIONS. 1 = timed
1.
1.
1.
/
8426 ST1 TRIG TO
VAL.
1.
1.
is set to, eg,
AI 1 HIGH
is set to, eg,
AI 1 LOW
is set to, eg,
AI 2 HIGH
Def/FbEq
11
12
13
14
15
NOT SEL
0
1
2
3
NOT SEL
NOT SEL
8407 SEQ
0
1
2
3
NOT SEL
0.0%
1.
1 = 0.1%
0.0%
1.
1 = 0.1%
0.0%
1.
1 = 0.1%

Hide quick links: