186 Actual signals and parameters
Actual signals
No.
Name/Value
0167 SEQ PROG
STS
0168 SEQ PROG
STATE
0169 SEQ PROG
TIMER
0170 SEQ PROG AO
VAL
0171 SEQ CYCLE
CNTR
0172 ABS TORQUE Calculated absolute value of the motor torque as a
0173 RO 2-4
STATUS
0179 BRAKE TORQ
MEM
0180 ENC
SYNCHRONIZ
ED
0181 EXTENSION
03 FB ACTUAL
SIGNALS
0301 FB CMD
WORD 1
0302 FB CMD
WORD 2
Description
Status word of the Sequence programming:
Bit 0 = ENABLED (1 = enabled)
Bit 1 = STARTED
Bit 2 = PAUSED
Bit 3 = LOGIC VALUE (logic operation defined by
parameters 8406...8410).
Active state of the Sequence programming. 1...8 = state
1...8.
Current state time counter of the Sequence programming
Analog output control values defined by the Sequence
programming. See parameter
Executed sequence counter of the Sequence programming.
See parameters
8415 CYCLE CNT LOC
CNT
RST.
percentage of the motor nominal torque
Status of the relays in the MREL-01 output relay module.
See MREL-01 output relay module user's manual
(3AUA0000035974 [English]).
Example: 100 = RO 2 is on, RO 3 and RO 4 are off.
Vector control: Torque value (0...180% of the motor nominal
torque) saved before the mechanical brake is taken in use.
Scalar control: Current value (0...180% of the motor
nominal current) saved before the mechanical brake is
taken in use.
This torque or current is applied when the drive is started.
See parameter
4307 BRK OPEN LVL
Monitors the synchronization of the measured position with
the estimated position for permanent magnet synchronous
motors. 0 = NOT SYNC, 1 = SYNC.
Shows which optional extension module is connected to the
drive. 0 = NONE, 1 = EXTENSION MREL-01,
2 = EXTENSION MTAC-01, 3 = EXTENSION MPOW-01
Data words for monitoring the fieldbus communication
(read-only). Each signal is a 16-bit data word.
Data words are displayed on the panel in hexadecimal
format.
A 16-bit data word. See section
on page 333.
A 16-bit data word. See section
on page
333
8423 ST1 OUT
CONTROL.
and
8416 CYCLE
SEL.
DCU communication profile
DCU communication profile
FbEq
1 = 1
1 = 1
1 = 2 s
1 = 0.1%
1 = 1
1 = 0.1%
1 = 0.1%
1 = 1
1 = 1