S.tune - Enabling Self-Tuning - gefran 650 Installation And Instruction Manual

Pid temperature controllers
Hide thumbs Also See for 650:
Table of Contents

Advertisement

4.13.1. S.TUNE - Enabling Self-Tuning

Acronym
S.TUNE
SELF TUNING ENABLE
The parameter shows and sets enabling of Self-Tuning.
For more information on the Self-Tuning function, see paragraph "5.10.3. Self-Tuning" on page 145.
Unit of measurement:
Options:
OFF
On
On.AL
4.13.2. SOFT.S - Enabling Soft-Start
Acronym
SOFT.S
SOFT START ENABLE
The parameter shows and sets enabling of Soft-Start.
For more information on the Self-Start function, see paragraph "5.9. Soft-Start" on page 144.
This parameter appears only if S.TUNE = OFF.
Unit of measurement:
Options:
OFF
On
4.13.3. SOFT.T - Soft-Start Time
Acronym
SOFT.T
SOFT START TIME
The parameter shows and sets Soft-Start time, i.e., the time that the control output needs to reach the value required by
the PID.
This parameter appears only if SOFT.S = On.
Unit of measurement:
Options:
0.0...500.0
4.13.4. A.TUNE - Enabling Auto-Tuning
Acronym
A.TUNE
AUTO TUNING ENABLE
The parameter shows and sets enabling of Auto-Tuning.
For more information on the Auto-Tuning function, see paragraph "5.10.4. Auto-Tuning" on page 146.
Unit of measurement:
Options:
OFF
On
80208G_MHW_650-1250-1350_01-2017_ENG
Scrolling message
-
= Self-Tuning disabled
= Self-Tuning enabled at next power-on only
= Self-Tuning enabled at all power-ons
Scrolling message
-
= Soft-Start disabled
= Soft-Start enabled at next power-on
Scrolling message
Minutes
Scrolling message
-
= Auto-Tuning disabled
= Auto-Tuning enabled
4. CONFIGURATION
Submenu
Attributes
PID
R W
Submenu
Attributes
PID
R W
Submenu
Attributes
PID
R W
Submenu
Attributes
PID
R W
85