UNIT OPERATION

7.3.1 ADJUSTING THE COMBUSTION LEVEL (HEAT OUTPUT)

PLENUM
148°F
Burn rate
adjustment
Burn rate
The stove's input range goes from 50,000 BTU to 100,000 BTU. To change combustion level, select the flame
on the main page to display the "+" and "-" combustion level settings.
icon
Note: Input range may vary according to the type of pellets being used.
Even though your furnace can burn a large variety of wood pellets, we strongly recommend the use of high-
quality pellets to obtain maximum performance out of your furnace (see Section 6.2.1 Proper Fuel). When
using lower quality combustible, a restrictive venting system or using the stove at high altitude, you may need to
adjust the "PILOT SETTING ADJUSTMENT" and the "FUEL QUALITY ADJUSTMENT". These two (2) settings
are available from the "PELLET SETUP" page.
Note: To obtain optimal results make sure the venting system, heat exchanger and exhaust channels are
cleaned before performing any setting changes.

7.3.2 COMBUSTION SETTINGS AND PILOT SETTINGS DEPENDING ON FUEL QUALITY