3.1

WOOD ADD-ON

3.1.1 INSTALLATION MINI-CADDY ADD-ON

3.1.2 INTRODUCTION

The wood burning Mini-Caddy Add-on furnace is approved for in-line connection
to an existing oil furnace with a firing rate of 0.8 G.P.H. (US) to 1.2 G.P.H. (US)
or any gas or electric furnace with comparable heat output. The existing furnace
must have a maximum heating capacity of 20,51 kW (75,000 BTU/h.)

3.1.3 APPLIANCE INSTALLATION

Before installation, please read the instructions carefully and make sure
you understand them:
The furnace must be installed in a state of the art manner. Installation must be
made in accordance with the CSA B.365 standard concerning the normalization
of solid fuel units. If modifications have to be made to the existing furnace, these
have to be conform respectively to CSA B.139 for oil furnaces, CSA C22.1 for
electric furnace and CAN/CSA B149.1 or CAN/CSA B149.2 for gas furnaces.
Inspect the furnace to make sure that nothing has been damaged in the shipping.
Pull out the wiring kit and the instructions manual from the firebox of the furnace
and the scraper from the flue pipe.

3.1.4 UNIT LOCATION

The furnace must be installed where outside air supply will be sufficient for
proper combustion. In airtight houses, it might be necessary to install an outside
air inlet (see Section 2.12.)
The furnace must be positioned so that the connector is as short as possible.
o
Minimize the use of 90
elbows.
The owner must ensure a proper installation to allow a safe operation of
the appliance.