For connection, refer to wiring diagram.
WARNING:
USE WIRING SUITABLE FOR 75 °C
(not included).

9.6. UNIT LOCATION

For a safe and quiet operation, the furnace must be leveled in both directions and supported evenly to ensure stability.
The furnace must be installed where outside air supply will be sufficient for proper combustion. In airtight houses, it
might be necessary to install an outside air inlet (See Section 9.11 - COMBUSTION AIR AND FRESH AIR INTAKE
ADAPTER INSTALLATION (OPTIONAL))
The furnace must be positioned so that the connector is as short as possible. Minimize the use of 90
The owner must ensure a proper installation to allow a safe operation of the appliance.

9.7. MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS AND FLOOR PROTECTION

N.B.: This appliance must be installed in accordance with the instructions on the certification plate
applied on the unit.
THE INSTALLATION OF THE HEAT SHIELD (-1-) PROVIDED WITH THE FURNACE IS
MANDATORY.
o
elbows.