If the rise is higher than 10 feet, a two stage pump may be required along with an oil return pipe.

3. APPLIANCE INSTALLATION

A- LOCATING THE UNIT

The furnace must be installed in a location where combustion air is available in sufficient quantity. In
airtight houses, the installation of an outside air intake might be required. (See details in 3- APPLIANCE
INSTALLATION, E- COMBUSTION AIR).
The owner is responsible for ensuring a proper installation to allow a salubrious operation of the
appliance.
Position the furnace so that the connecting pipe is as short as possible and limit the use of 90
a minimum.
Provide sufficient clearance to permit easy access for maintenance of the filters, motors, controls and
pipe connectors.
The furnace is not to be installed on a combustible floor.
B. CLEARANCES TO COMBUSTIBLE MATERIALS
WARM AIR PLENUM AND FIRST 6 FEET OF DUCT
PLENUM AFTER THE FIRST 6 FEET
OIL BURNING UNIT FLUE PIPE
*A floor protection exceeding the unit 8" on sides and 18" in the front, should be used
when installed on a combustible floor.

C- POSITIONING THE APPLIANCE

For a safe and quiet operation, the furnace must be levelled in both directions. Give each "U" shape block, an equal
support so that the weight is evenly distributed.
under each "U" runner

D- PIPE CONNECTOR AND DAMPER

The pipe connecting the furnace to the chimney must be as short as possible. The use of 45
recommended for a better evacuation of the smoke in the chimney. The draught regulator must be installed in a
straight length of pipe no more than 18 inches from the furnace exit pipe and adjusted at .02'' w.c.
MINIMUM INSTALLATION CLEARANCES
TO COMBUSTIBLE MATERIALS
REAR
SIDES
* FLOOR
Prior to positioning the furnace, install the rubber supports
5
o
elbows to
2 in. (51 mm)
1 in. (25 mm)
24 in. (610 mm)
6 in. (152 mm)
9 in. (229 mm)
0 in. (0 mm)
o
elbows is highly