Installation Of An Air-Conditioning Unit - PSG CADDY ALTERNA II Installation And Operating Instructions Manual

Pellet furnace
Table of Contents

Advertisement

L-170 Thermodisc
RESET
When the call for heat cannot be satisfied by pellet heating (fuel shortage, error codes, etc.), the electrical
element will automatically take over to maintain the house at the temperature set on the thermostat.

5.15 INSTALLATION OF AN AIR-CONDITIONING UNIT

The Caddy Alterna II pellet furnace has been tested with an optional air-conditioning unit. If this option is
chosen, we recommend an installation as per the graphic provided below. This installation will provide the most
efficient and safe operation of the air conditioning coil unit using the distribution blower of the Caddy Alterna II
furnace during summer. In order to complete the installation of an air-conditioning unit, the thermostat must be a
"heat/cool" type. Furthermore, the desired distribution blower speed in the air conditioning mode will have to be
programmed on the LCD screen in the blower speed menu (see sections 7.2.4: Setting the distribution fan
Speeds). Note that upon thermostatic demand for cooling, the distribution blower will start immediately at the
selected speed. For the air conditioning damper wiring, see Section 15.4 Air conditioning damper.
The capacity and characteristics of the air-conditioning unit that has been tested for the Caddy Alterna II are
stated below. The use of another model with similar capacity and characteristics is adequate.
Condenser brand: Goodman GSX13036
Capacity: 4 tons
Coil type: Type A, CAUF (uncased indoor coil).
INSIDE VIEW OF THE ELECTRIC ELEMENT
37
Red button manual
reset

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pf09010

Table of Contents