15.5. UNIT LOCATION

For a safe and quiet operation, the add-on must be leveled in both directions and supported evenly to ensure stability.
The add-on must be installed where outside air supply will be sufficient for proper combustion. In airtight houses, it
might be necessary to install an outside air inlet (See Section 15.13 - COMBUSTION AIR AND FRESH AIR INTAKE
ADAPTER INSTALLATION (OPTIONAL))
The add-on must be positioned so that the connector is as short as possible. Minimize the use of 90
The owner must ensure a proper installation to allow a safe operation of the appliance.

15.6. MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS AND FLOOR PROTECTION

N.B.: This appliance must be installed in accordance with the instructions on the certification plate
applied on the unit.
THE INSTALLATION OF THE HEAT SHIELD (-1-) PROVIDED WITH THE ADD-ON IS
MANDATORY.

15.7. MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS

28
o
elbows.