STEP 5: Connect the RTD probe
(B) to the furnace block terminal
identified with a "R".
STEP 6: Use the wire grommets (C)
supplied with the manual to attach
the wires from the RTD to the
furnace.
11.3 UNIT LOCATION
For a safe and quiet operation, the furnace must be leveled in both directions and supported evenly to ensure
stability.
The furnace must be installed where outside air supply will be sufficient for proper combustion. In airtight
houses, it might be necessary to install an outside air inlet. See section 11.8 FRESH AIR SUPPLY
INSTALLATION
The furnace must be positioned so that the chimney connector is as short as possible. Minimize the use of 90
elbows.
The owner must ensure a proper installation to allow a safe operation of the appliance.
11.4 MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS AND FLOOR PROTECTION
This appliance must be installed in accordance with the instructions on the certification plate applied on
the unit.
o
19