GE G30 Instruction Manual page 640

Generator protection system 7.6x
Hide thumbs Also See for G30:
Table of Contents

Advertisement

FLEXANALOG ITEMS
Address
FlexAnalog name
5832
Field TDR 1 Value
A
5834
Field TDR 2 Value
5836
Field TDR 3 Value
5838
Field TDR 4 Value
5840
Field TDR 5 Value
5842
Field TDR 6 Value
5844
Field TDR 7 Value
5846
Field TDR 8 Value
5856
Freq Rate 1 Value
5860
Freq Rate 2 Value
5864
Freq Rate 3 Value
5868
Freq Rate 4 Value
6144
SRC 1 Ia RMS
6146
SRC 1 Ib RMS
6148
SRC 1 Ic RMS
6150
SRC 1 In RMS
6152
SRC 1 Ia Mag
6154
SRC 1 Ia Angle
6155
SRC 1 Ib Mag
6157
SRC 1 Ib Angle
6158
SRC 1 Ic Mag
6160
SRC 1 Ic Angle
6161
SRC 1 In Mag
6163
SRC 1 In Angle
6164
SRC 1 Ig RMS
6166
SRC 1 Ig Mag
6168
SRC 1 Ig Angle
6169
SRC 1 I_0 Mag
6171
SRC 1 I_0 Angle
6172
SRC 1 I_1 Mag
6174
SRC 1 I_1 Angle
6175
SRC 1 I_2 Mag
6177
SRC 1 I_2 Angle
6178
SRC 1 Igd Mag
6180
SRC 1 Igd Angle
6208
SRC 2 Ia RMS
6210
SRC 2 Ib RMS
6212
SRC 2 Ic RMS
6214
SRC 2 In RMS
6216
SRC 2 Ia Mag
6218
SRC 2 Ia Angle
6219
SRC 2 Ib Mag
6221
SRC 2 Ib Angle
6222
SRC 2 Ic Mag
6224
SRC 2 Ic Angle
6225
SRC 2 In Mag
6227
SRC 2 In Angle
A-2
Units
Description
---
Field TDR 1 value
---
Field TDR 2 value
---
Field TDR 3 value
---
Field TDR 4 value
---
Field TDR 5 value
---
Field TDR 6 value
---
Field TDR 7 value
---
Field TDR 8 value
Hz/s
Frequency rate of change 1 actual value
Hz/s
Frequency rate of change 2 actual value
Hz/s
Frequency rate of change 3 actual value
Hz/s
Frequency rate of change 4 actual value
Amps
Source 1 phase A current RMS
Amps
Source 1 phase B current RMS
Amps
Source 1 phase C current RMS
Amps
Source 1 neutral current RMS
Amps
Source 1 phase A current magnitude
Degrees
Source 1 phase A current angle
Amps
Source 1 phase B current magnitude
Degrees
Source 1 phase B current angle
Amps
Source 1 phase C current magnitude
Degrees
Source 1 phase C current angle
Amps
Source 1 neutral current magnitude
Degrees
Source 1 neutral current angle
Amps
Source 1 ground current RMS
Amps
Source 1 ground current magnitude
Degrees
Source 1 ground current angle
Amps
Source 1 zero-sequence current magnitude
Degrees
Source 1 zero-sequence current angle
Amps
Source 1 positive-sequence current magnitude
Degrees
Source 1 positive-sequence current angle
Amps
Source 1 negative-sequence current magnitude
Degrees
Source 1 negative-sequence current angle
Amps
Source 1 differential ground current magnitude
Degrees
Source 1 differential ground current angle
Amps
Source 2 phase A current RMS
Amps
Source 2 phase B current RMS
Amps
Source 2 phase C current RMS
Amps
Source 2 neutral current RMS
Amps
Source 2 phase A current magnitude
Degrees
Source 2 phase A current angle
Amps
Source 2 phase B current magnitude
Degrees
Source 2 phase B current angle
Amps
Source 2 phase C current magnitude
Degrees
Source 2 phase C current angle
Amps
Source 2 neutral current magnitude
Degrees
Source 2 neutral current angle
G30 GENERATOR PROTECTION SYSTEM – INSTRUCTION MANUAL
APPENDIX A: FLEXANALOG OPERANDS

Advertisement

Table of Contents
loading

Table of Contents