2.2.2

Connecting the Debugging MCU Board to the User System

To connect the debugging MCU board to the user system, follow the instructions below.
Always switch OFF the emulator product, the debugging
MCU board, and the user system before any connection or
removal of the USER SYSTEM INTERFACE BOARD.
Furthermore, make sure that the pin 1 positions on both
sides are correctly aligned. Failure to do so will create a
FIRE HAZARD that can damage the emulator product, the
debugging MCU board, the user system interface board, or
the user system, or produce PERSONAL INJURY.
1. Solder the IC socket to the user system.
Before applying solder, use epoxy resin adhesive to affix
the guide points on the IC socket to the user system.
Ensure full wetting of the leads so that the solder flows
over the leads and forms good fillets (use slightly more
solder than you normally would).