Renesas H8/33937 User Manual
Renesas H8/33937 User Manual

Renesas H8/33937 User Manual

User system interface cable for e6000 emulator

Advertisement

Quick Links

To our customers,
st
On April 1
, 2010, NEC Electronics Corporation merged with Renesas Technology
Corporation, and Renesas Electronics Corporation took over all the business of both
companies. Therefore, although the old company name remains in this document, it is a valid
Renesas Electronics document. We appreciate your understanding.
Issued by: Renesas Electronics Corporation (http://www.renesas.com)
Send any inquiries to http://www.renesas.com/inquiry.
Old Company Name in Catalogs and Other Documents
Renesas Electronics website:
http://www.renesas.com
st
April 1
, 2010
Renesas Electronics Corporation

Advertisement

Table of Contents
loading

Summary of Contents for Renesas H8/33937

  • Page 1 On April 1 , 2010, NEC Electronics Corporation merged with Renesas Technology Corporation, and Renesas Electronics Corporation took over all the business of both companies. Therefore, although the old company name remains in this document, it is a valid Renesas Electronics document. We appreciate your understanding.
  • Page 2 Renesas Electronics. Renesas Electronics shall not be in any way liable for any damages or losses incurred by you or third parties arising from the use of any Renesas Electronics product for an application categorized as “Specific”...
  • Page 3 H8/3937R H8/33937 Series TFP-100B User System Interface Cable (HS3937ECH61H) for E6000 Emulator User’s Manual...
  • Page 4 1. Renesas neither warrants nor grants licenses of any rights of Renesas’s or any third party’s patent, copyright, trademark, or other intellectual property rights for information contained in this document. Renesas bears no responsibility for problems that may arise with third party’s rights, including intellectual property rights, in connection with use of the information contained in this document.
  • Page 5 Preface Thank you for purchasing this user system interface cable (HS3937ECH61H) for the Renesas’s original microcomputer H8/3937R H8/3937 series. The HS3937ECH61H is a user system interface cable that connects an H8/300L series E6000 emulator (HS388REPI60H; hereinafter referred to as the emulator) through the expansion board to...
  • Page 6: Table Of Contents

    Section 1 Configuration...1 Section 2 Connection Procedures ...3 Connecting User System Interface Cable to Emulator Station ... 3 Connecting User System Interface Cable to User System ... 5 2.2.1 Installing IC Socket ... 5 2.2.2 Soldering IC Socket ... 5 2.2.3 Inserting Cable Head ...
  • Page 7: Section 1 Configuration

    Section 1 Configuration Use an IC149-100-054-B51 socket (manufactured by YAMAICHI ELECTRONICS Co., Ltd.) for the TFP-100B package IC socket on the user system. Figure 1 shows the configuration of the HS3937ECH61H user system interface cable for the TFP-100B package. Figure 1 HS3937ECH61H User System Interface Cable CAUTION...
  • Page 8 Table 1 lists the HS3937ECH61H components. Please make sure you have all of these components when unpacking. Table 1 HS3937ECH61H Components No. Component Cable body Cable head IC socket Socket cover Screws (M2.6 x 12 mm) Screws (M2.6 x 6 mm) Documentation Quantity Remarks...
  • Page 9: Section 2 Connection Procedures

    Section 2 Connection Procedures Connecting User System Interface Cable to Emulator Station Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY.
  • Page 10 2. [1] After making sure the direction of the expansion board connector labeled E6000 EMULATOR is correct, firmly insert the expansion board connector into the emulator station connector ([1] in figure 2). [2] Connect the expansion board labeled USER INTERFACE CABLE and the user system interface cable body.
  • Page 11: Connecting User System Interface Cable To User System

    Connecting User System Interface Cable to User System Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 on both sides are correctly aligned.
  • Page 12: Inserting Cable Head

    2.2.3 Inserting Cable Head Check the location of pin 1 before inserting. Align pin 1 on the IC socket for an TFP-100B package on the user system with pin 1 on the user system interface cable head, and insert the user system interface cable head into the IC socket on the user system, as shown in figure 3.
  • Page 13 Fasten the user system interface cable head to the IC socket for an TFP-100B package on the user system with the four screws (M2.6 12 mm; with flat washers) provided. Each screw should be tightened a little at a time, alternating between screws on opposing corners. Take special care, such as manually securing the IC socket soldered area, to prevent the soldered IC socket from being damaged by overtightening the screws or twisting the components.
  • Page 14: Fastening Cable Body

    2.2.5 Fastening Cable Body Connect the cable body to the cable head. Cable body Removing Push the remove jig Remove jig Cable head User system Figure 4 Fastening Cable Body...
  • Page 15: Recommended Dimensions For User System Mount Pad

    Recommended Dimensions for User System Mount Pad Figure 5 shows the recommended dimensions for the mount pad (footprint) for the user system with an IC socket for an TFP-100B package (IC149-100-054-B51: manufactured by YAMAICHI ELECTRONICS Co., Ltd.). Note that the dimensions in figure 5 are somewhat different from those of the actual chip's mount pad.
  • Page 16: Dimensions For User System Interface Cable Head

    Dimensions for User System Interface Cable Head The dimensions for the user system interface cable head are shown in figure 6. Figure 6 Dimensions for User System Interface Cable Head...
  • Page 17: Resulting Dimensions After Connecting User System Interface Cable

    Resulting Dimensions after Connecting User System Interface Cable The resulting dimensions, after connecting the user system interface cable head to the user system, are shown in figure 7. Figure 7 Resulting Dimensions after Connecting User System Interface Cable...
  • Page 18: Section 3 Installing The Mcu To The User System

    Section 3 Installing the MCU to the User System 1. Check the location of pin 1 before inserting. 2. Use a Philips-type screwdriver whose head matches the screw head. 3. The tightening torque must be 0.054 N•m or less. If the applied torque cannot be accurately measured, stop tightening when the force required to turn the screw becomes significantly greater than that needed when first tightening.
  • Page 19 Figure 8 Installing MCU to User System...
  • Page 20: Section 4 Verifying Operation

    Section 4 Verifying Operation 1. When using the H8/300L series E6000 emulator (HS388REPI60H), turn on the emulator according to the procedures described in the H8/300L Series E6000 Emulator User's Manual (HS388REPI60HE). 2. Verify the user system interface cable connections by accessing ports and checking the bus states of the pins.
  • Page 21 Figure 9 shows the Expansion I/O board Subclock Selection, and figure 10 shows the location of jumpers P4 and P5. Figure 11 shows the system clock oscillator on the user system interface cable and the subclock input specifications. Subclock selection Figure 9 Expansion I/O board Subclock Selection Figure 10 P4 and P5 Jumpers Figure 11 System Clock Oscillator and Subclock Input Specifications...
  • Page 22: Section 5 Notice

    1. Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cable head before inserting the cable head into the user system IC socket. 2. The dimensions of the recommended mount pad for the user system IC socket are different from those of the MCU.

This manual is also suitable for:

H8/3937rHs3937ech61h

Table of Contents