8) The sending of set signals can now be programmed to be sent immediately upon setting or at the end of the exit
delay (refer P322E, P324E and P326E).
ADDITIONAL FEATURES WITH V4.21 SOFTWARE
1)On powering up the panel with the panel tamper open tamper alarms are inhibited as before but the panel does
not now default to putting keypad 1 into program mode.Instead, all keypads on the system start up in normal mode
and you may now go to any keypad connected to the panel and the first button press will automatically put that
keypad into full program mode.
2)You can now select one of two 300Baud modem formats,either Bell103 or V21.(P719E Option8).This allows for
the modern high speed modems which may only support one of these formats.You can also set the modem level
generated by the panel at address P727E Option 7 & 8.If both 7 & 8 are off the level is LOW,if 7 is on the level is
MEDIUM,and if 7 is off and 8 is on the level is HIGH.The default setting is Medium which is recommended for most
situations.
3)At addresses P180E,P280E & P380E Option8 you can now select an option to ignore zone tamper alarms during
the exit delay.This feature has been provided so that smoke detectors with trouble or power supervisory outputs can
be automatically reset on arming without causing a trouble alarm.(Assuming the zone tamper indication is used to
monitor the trouble signal)
NEW FEATURES WITH V5.0 SOFTWARE
1)The siren driver option for outputs 1 & 2 are now a hardware device rather than the previous software driven
outputs.The siren driver to outputs 1 & 2 are now set by 2 links on the main control board(refer to diagram on page
10).If the links are fitted then outputs 1 & 2 are switched outputs designed to drive 12v devices,if the links are
removed then the outputs are modulated siren outputs designed to drive horn speakers.Link 1 relates to output 1
and link 2 relates to output 2.
2)The listen-in feature available at the keypads can now be assigned to output 1 as well via the listen-in link on the
main control board(refer to diagram on page 10).The link should only be fitted if a horn speaker is wired to output 1
otherwise the link should be left off.
3)Access to program mode can now be further defined for each of the 24 user codes e.g users can have access to
program mode to view and change their code only,access program mode to view and change all user codes and
gain access to installer program mode via client program mode.
The installer code can also now be programmed to allow access directly into full program mode without having to go
via client program mode first,however as a safety feature the panel must not be armed or in monitor mode to allow
this to happen.
4)The panel now allows the entry delay timer for each of the 16 zones to be assigned to 24 hour zones to provide
an abort delay for these zones.If the entry delay for a 24 hour zone is set to 0 then the alarm is instant.If the entry
delay is set to a value other than 0 ,e.g 600,then the zone has to be in alarm for 10 minutes before it will activate.If
the zone seals before the 10 minutes expires then the delay is reset and no alarm is created.This feature is very
useful for plant monitoring.
5)There is now a new set of program addresses for the communicator (P215,P216,P217 & P218).These 4
addresses allow a maximum number of dial attempts for each of the 4 dialling scenario's.Now if you need to restrict
the number of calls which will be made following an alarm these new program options will allow you to control the
maximum calls.