Intek Elite 16D Installation & Programming Manual page 53

16 zone control communicator
Table of Contents

Advertisement

Option 1
Enable Communicator - This option is used to activate the communicator hardware. If this
option is not assigned, all communicator activity, including recording messages on the speech
dialler module, will be disabled. - Default = Communicator Off
Option 2
DTMF or Decadic.Selects touchtone dialling.led must be ON
Option 3
NZ Style Decadic - With this option off, the deladic pulses are NZ style pulses. If the option is
on, then the pulses are reversed
Option 4
Blind Dial - If this option is selected, the communicator will make a dial attempt even if it can not
detect a valid dial tone. If this option is not selected the communicator will seize the phone line
and listen for dial tone. If dial tine is not present the communicator will release (Hang up) the
line wait five seconds and repeat the process. If dial tone is still not present after 3 attempts the
communicator will Blind Dial. On = Blind Dial, off = Standard Dial. - Default = Off
Option 5
Send Restores - If this option is selected restores will be reported for all events. If this option is
not selected restores will be disabled. On = Send Restores, off = No Restores. - Default = On
Option 6
Use Group Codes or Multiple Accounts - This option is used to determine if system using
multiple Areas will use Group Code reporting to one account number or report individual Area
activity to individual account numbers. Option 6 on = group code and option 6 off = multiple
account numbers - Default = Off.
Option 7
Fax Defeat - This option enables fax defeat mode. When enabled the panel will look for
incoming rings between 2-6 rings (inclusive). If the incoming call is then terminated the panel
will answer the next incoming call within 2 rings. If another call is not established within 60 sec
of the first call, the fax defeat mode is reset. For fax defeat to work the auto answer rings must
be enabled by putting in a suitable ring count (eg 15).
Option 8
Disable Line Monitoring -If this option is enabled, then the panel no longer tests the telephone
line.
AREA ACCOUNT CODES - P266E - P268E
P266E
XXXXE Account Code for Area "A" Reports - The Account code set at this address will be used to
report all system events sets and unsets, zone activations, restores and excludes etc from Area
"A" - Default Account = 0000
P267E
XXXXE Account Code for Area "B" Reports - The account code set at this address will be used to
report sets and unsets, zone activations, restores and excludes etc from Area "B"
P268E
XXXXE Account Code for Area "C" Reports - The account code set at this address will be used to
report sets and unsets, zone activations, restores and excludes etc from Area "C"
COMMAND CONTROL CODES P261E - P264E
P261E
XXXXE DTMF Command Output Control Code - This is a 4 digit code used to control the 8 outputs
either locally (set by options P101 - P108 opt 6) or by DTMF remote (set by options P101 - P108
opt 5)
P262E
XXXXE DTMF Command Code For Area A - This is a 4 digit code used to remotely set/unset Area A.
P263E
XXXXE As per P262E but controls Area B.
P263E
XXXXE As per P262E but controls Area C.
P680E
1-9E
Starting message number to command control voice prompts.