OUTPUT OPTIONS FIRST SET- P101E-P108E
This block of addresses (P101E - P108E) are used to map output modifiers to each of the 8 outputs available on the
Elite. Note: Only 5 outputs are available on the Elite mother board. The additional outputs are available on the
Output Expander module.
P101E
1E
Invert output #1 - Default off
2E
Flash output #1 - Default off
3E
Single pulse to output #1 - Default off
4E
Lockout output #1 once reset - Default off
5E
Output mapped to Remote Command Control - Default off
6E
Output mapped to local Command Control - Default off
7E
Day zones linked to pulse timer - Default off
8E
Spare
Option 1
Invert Output - This option is used to invert the normal state of the output. The Elite uses open
collector type transistor switches and the default state of all outputs is off or high. When in alarm the
transistor switch is turned on and the output is switched low. The invert option reverses this function.
Option 2
Flash Output - This option causes the output to switch on and off at 2 second intervals when in alarm
and is normally used to flash a lamp during an activation.
Option 3
Single Pulse to Output - This option, when applied, produces a single 1 second pulse at the output
during an alarm (the pulse time is the value programmed at the output pulse timer address).
Option 4
Lockout Once Reset - This option is used to limit the output to one operation per arming period.
Option 5
Output mapped to Remote Command Control - This option is used to map an output to the remote
command control function whereby the output can be controlled via the telephone (this requires the
optional speech board unit)
Option 6
Output mapped to Local Command Control - This option is used to map an output to the local
command control feature whereby the output can be controlled directly from the keypad.
Option 7
Day Zones Linked to Pulse Timer - Day Zones programmed to this output will pulse at the pulse timer
rate (P441E) for the duration of the day zone to keypad timer (e.g. if the day zone is in partition A, then
the timer at P457E applies)
Option 8
Spare
P102E - P108E
As per P101E above for Outputs 2-8
OUTPUT OPTIONS SECOND SET - P111E - P118E
In this block of addresses P111E relates to output #1, P112E relates to output #2 etc
Page 20