P662E
1-8E
Voice Messages Mapped to Zone 2 Activation's - Default 1
P663E
1-8E
Voice Messages Mapped to Zone 3 Activation's - Default 1
P664E
1-8E
Voice Messages Mapped to Zone 4 Activation's - Default 1
P665E
1-8E
Voice Messages Mapped to Zone 5 Activation's - Default 1
P666E
1-8E
Voice Messages Mapped to Zone 6 Activation's - Default 1
P667E
1-8E
Voice Messages Mapped to Zone 7 Activation's - Default 1
P668E
1-8E
Voice Messages Mapped to Zone 8 Activation's - Default 1
P669E
1-8E
Voice Messages Mapped to Zone 9 Activation's - Default 1
P670E
1-8E
Voice Messages Mapped to Zone 10 Activation's - Default 1
P671E
1-8E
Voice Messages Mapped to Zone 11 Activation's - Default 1
P672E
1-8E
Voice Messages Mapped to Zone 12 Activation's - Default 1
P673E
1-8E
Voice Messages Mapped to Zone 13 Activation's - Default 1
P674E
1-8E
Voice Messages Mapped to Zone 14 Activation's - Default 1
P675E
1-8E
Voice Messages Mapped to Zone 15 Activation's - Default 1
P676E
1-8E
Voice Messages Mapped to Zone 16 Activation's - Default 1
P679E
1-8E
Voice Message Mapped to Battery Low Alarm - Default 0
P718E
XXXXXXXX. Up
to 8 digit security code for
upload/download.
P719E

Upload/Download options

1E Data transfer is allowed -Default on
2E Can get data "from panel" - Default on
3E Can send data "to panel" - Default on
4E Can monitor keypad activity - Default on
5E Can monitor panel status - Default on
6E Can change panel status - Default on
7E Can clear event buffer
8E V21/Bell103
Option 1
Data Transfer is Allowed - this option must be on for ANY panel -pc data transfer to occur (if
off connection can still be achieved with P728E command as below).
Option 2
Can Get Data "From Panel" - this option must be on to allow the pc to retrieve programmed
data from the panel.
Option 3
Can Send Data "To Panel" - to allow changes to be sent to the panel from the pc, this option
plus options 1 & 2 must be on.
Option 4
Can Monitor Keypad Activity - this option allows an operator to view the last 16 keypad buss
entries at a panel via a dial-up link. To work this option plus options 1 & 2 must be on.
Option 5
Can Monitor Panel Status - this option allows display of the partitions, zones, outputs, mains
and battery status. The option must be on with options 1 & 2.
Option 6
Can Change Panel Status - this option allows control of setting/unsetting for partitions A,B & C,
control of the 8 outputs and excluding of zones via the pc upload/download dial up link. This
option must be on with options 1,2 & 5.
Option 7
Can clear event buffer-this option allows the user to clear the panels event buffer from
the PC
Option 8
V21/Bell103-if this option is off Bell103 format is selected,if on V21 format is selected.The
choice of either 300Baub format is dependent upon your modem.
Page 55