HOW TO PROGRAM

The programming sequence always follows this pattern;
Throughout this manual you will see program instructions expressed as
In this example the <P> represents the PROGRAM key and <E>represents the ENTER key.

ACCESS TO PROGRAMMING ON POWER UP

When power is applied to the controller for the first time, with the panel tamper input open, the panel will inhibit
tamper alarms and ready the panel to enter PROGRAM Mode( unless the Installer Lock-out option P201E6E has
previously been enabled.)At this point you can go to any keypad which is connected to the panel and the first button
press will automatically put that keypad into full Program mode.(NOTE:Only one keypad can be in Program mode at
any time)

ACCESS TO PROGRAM MODES FROM RUN MODE

Before you can enter program mode, the panel must be unset with no monitor mode.
You are now in Client Program Mode. When you are in Client programming mode you have access to program
addresses P1E to P24E. To enter Install Program Mode
TO CLEAR PROGRAM INFORMATION (From Install Mode Only)
There are five options available for clearing program information (Reset to
defaults). These are detailed on page 38.
e.g.To reset User Codes 1-24 (P 741 E)
e.g.To reset Radio Defaults (P 743 E)
After the system configuration or User Codes have been reset, all values, options & Codes will be set to the values
shown in the Program Option Summary as defaults. These value & option selections have been chosen as the most
common set-up for the majority of systems.
<PROGRAM> - <2 or 3 digit address> - <ENTER>
3 short beeps if OK - 1 long beep if error
The leds will display current value or status
Enter the new value or option
<New Value> - <ENTER>
3 short beeps if OK - 1 long beep if error
P 23 E 5 E as an example.
Press <PROGRAM> - <Code 1(or Master Code)> - <ENTER>
Program light steady
Note: Default Master Code (Code 1) is 123
Press <PROGRAM> - <Install Code> - <ENTER>
Program light flashing
Note: Default Install Code (P99) is 000000
Press <PROGRAM> - 741 - <ENTER>
3 beeps - Program light flashing
Press <PROGRAM> - 743 - <ENTER>
3 beeps - Program light flashing
Page 17