P111E
1E
Keypad panic to Output #1
2E
Keypad Tampers to Output #1
3E
Zone Tampers to Output #1
4E
Cabinet Tamper to Output #1
5E
Radio Panic to Output #1
6E
Mains Fail to Output #1
7E
Battery Low to Output #1
8E
Phone Line Fail
Option 1
Keypad Panic to Output - This option is used to map the operation of the keypad panic button to an
output i.e. when the Panic button on a keypad is pressed any output with this option enabled will turn
on.
Option 2
Keypad Tampers to Output - This option is used to map Keypad Tampers to an output. Keypad
Tampers are generated when an invalid code is entered four times.
Option 3
Zone Tampers to Output - Where dual end-of-line resistors are being used to provide individual zone
tampers Option 3 at this address is used to map the Zone Tampers to an output.
Option 4
Cabinet Tamper to Output - This option is used to map activations of the common Tamper Input to an
output. This common tamper input is normally used to monitor the panel cabinet and satellite tamper
switches.
Option 5
Radio Panic to Output - This option will map the operation of a Radio pendant panic button to an
output. Programming of Radio Pendant options is found at P581E - P596E
Option 6
Mails Fail To Output - A mains failure will be indicated at this output when option 6 is enabled at this
address. The Alarm Reset Timer MUST NOT be used in conjunction wit this option.
Option 7
Low Battery - A battery Low condition will be indicated at this output when option 7 is enabled at this
address. The alarm reset timer MUST NOT be used in conjunction with this option.
Option 8 -
Phone Line Fail- A telephone line failure will be indicated at this output when option 8 is enabled at this