PARTITION "A" KEYPAD OPTIONS - P191E - P196E
P191E
1-8
Day Zone alarms to keypad buzzer (Default all) - This option will operate the keypad buzzer
when a day zone is activated. The duration of the buzzer is defined at P457E. Day zones are
those which are active during periods when the Area is unset.
P192E
1-8
Standard zone alarms to keypad buzzer (Default all) - This option will map standard zone
activations to the keypad buzzer. Normal zones are those which will only activate when the
partition is set
P193E
1-8
Monitor mode alarms to keypad buzzer (Default all) - This option will map activations from
zones defined as Monitor Mode to the keypad buzzer.
P194E
1-8
24 Hour alarms to keypad buzzer (Default all) - This option will map activations from zones
defined as 24 Hour to the keypad buzzer. 24 Hour zones are those which will activate whether
the Area is set or unset.
P195E
1-8
Exit beeps to keypad buzzer (Default all) - This option will produce beeps at the keypad during
the Exit delay. Pressing any button during the Exit period will cancel the beeps.
P196E
1-8
Entry beeps to keypad buzzer (Default all) - This option will produce beeps at the keypad
during the Entry Delay. Pressing the first digit of your user code will cancel the beeps.
P197E
0-9
Duress Digit (Default 0) - A Duress Alarm is activated only when the "Duress Digit" defined at
this address is prefixed to a valid Area "A" user code and entered at a keypad which has been
assigned Area "A" permissions. The resulting Duress Alarm will unset the Area in the normal
way, operate an output if one is defined and report a duress event via the communicator.
Values of 0-9 may be entered at this address where 0 = option disabled and 1-9 represent the
digits 1-9.
NOTE: At addresses P191E to P196E options 1-8 refer to keypads 1-8
PARTITION "A" TIME AND DELAY OPTIONS - P180E
P180E
1E set partition when time zone ends -Default off
2E unset partition when time zone starts - Default off
3E disable monitor mode exit delay - Default off
4E disable set mode exit delay - Default off
5E disable monitor mode entry delay - Default off
6E disable set mode entry delay - Default off
7E spare
8E disable zone tampers during exit delay time-Default off
Option 1
Set partition when time zone ends - this option will automatically arm partition "A" when the
time zone programmed at address P170E finishes.
Option 2
Unset partition when the time zone starts - this option will automatically disarm partition "A"
when the tme zone programmed at address P170E starts.
Option 3
Disable monitor mode exit delay. If this option is on the exit delay for partition "A" does not
apply to monitor mode.
Option 4
Disable set mode exit delay - if this option is on the exit delay for partition "A" does not apply
when setting (the delay will still apply to monitor mode unless option 3 is also on).
Option 5
Disable monitor mode entry delay - if this option is on then all zones are instant in monitor ode
regardless of any entry delays programmed to zones.
Option 6
Disable set mode entry delay - if this option is on then all zones are instant in full set mode
regardless of any entry delays programmed to zones (entry delays will still apply to zones in
monitor mode unless option 5 is also on).
Option 7
Spare
Option 8
Disable zone tampers during exit time.If this option is set then the zone tampers for this
Partition are ignored during the exit delay(useful for monitoring zone troubles on smoke
detectors)