P322E
1-8E
Area A Reporting Options - Default 1,2&4
Option 1
Send Set / Unset - If this option is enabled, the communicator will report Area "A" sets and
unsets following the steps as determined by the reporting scenario assigned by P323E
Option 2
Send Monitor On / Off - If this option is enabled, the communicator will report Area "A"
monitor on and monitor off events following the steps as determined by the reporting scenario
assigned by P323E
Option 3
Send Unsets only after activation - If this option is enabled, the communicator will report
Area A unsets (opens) after alarm activation only. This option is often used in conjunction with
alarm only reporting.
Option 4
Send Duress Alarms - If this option is enabled, the communicator will report Duress Alarms
as defined by address P197E
Option 5
Enable 24hr Alarms to Voice/Domestic - If this option is enabled, then 24hr zone alarms will
report using voice or domestic alarm tone reporting even when the alarm is unset.
Option 6
Send Set Immediately - If enabled, the communicator will report a set immediately the panel
is armed. If not enabled, the set report is sent at the expiry of the exit delay.
Option 7
Spare
Option 8
Spare
P323E
1-4E
Area "A" Reports mapped to Scenario 1-4 - This option is used to map Area "A" reports as
defined by P322E to one of the four possible reporting scenarios - Default 1
P324E
1-8E
Area "B" Reporting Options - Default 1,2&4
P325E
1-4E
Area "A" Reports mapped to Scenario 1-4 - Default 1
P326E
1-8E
Area "C" Reporting Options - Default 1,2&4
P327E
1-4E
Area "C" Reports mapped to Scenario 1-4 - Default 1
SYSTEM REPORTING OPTIONS - P329E, P260E, P264E, P265E & P266E
This block of addresses is used to define a number of global system options. Multiple options may be assigned at
address P260E
P329E
1-99E
Auto-Answer Rings - This options defines the number of rings before the communicator will
auto-answer the incoming call. A value of zero (0) at this address will disable auto-answer. -
Default = 0
P260E
1-8E
System Options
1 = Enable Communicator
2 = DTMF or Decadic
3 = NZ style Decadic
4 = Blind Dial
5 = Send Restores
6 = Use Group code or Multiple Accounts
7 = Fax defeat
8 = Disable line monitoring
Page 52
1 = Sent Set / Unset
2 = Send Monitor On/ Off
3 = Send Unset only after activations
4 = Send Duress Alarms
5 = Enable 24hr alarms to
voice/domestic
6 = send set immediately
7 = Spare
8 = Spare
Need help?