USER CODE PERMISSIONS (Code Options) 1st Set - P25E-P48E
Option 0 - Turns all options off
Option 1 - Code has Area A permissions
Option 2 - Code has Area B permissions
Option 3 - Code has Area C permissions
Option 4 - Code can Arm Area
Option 5 - Code can Disarm Area
Option 6 - Code can turn Monitor on
Option 7 - Code can turn Monitor off
Option 8 - Code can Operate control Functions
Option 9 - Turns all options on.
NOTE: Options 4, 5, 6 & 7 are used in conjunction with options 1, 2 & 3 whereby options 4, 5, 6 & 7 determine the
functions and options 1, 2 & 3 determine the area of operation.
USER CODE PERMISSIONS (Code Options) 2nd Set - P49E-P72E
Option 0 - Turns all options off
Option 1 - Code can override DOTL timer
Option 2 - Code can change dialler telephone numbers
Option 3 - Code can alter the real time clock
Option 4 - User can start a print dump of the event buffer
Option 5 - .User can answer an incoming call and start up/down load
Option 6 - User can enter Client Program and change their code only.
Option 7 - User can enter Client Program and change all codes.
Option 8 - User can enter Client Program mode and then Installer Program mode(if installer code is known).
Option 9 - Turns all options on.
USER CODE TIME ZONES - P73E-P96E
Users codes may have Time Zones or windows assigned to control their operation. These Time Zones determine
when a particular user code will work. Addresses P73E - P96E are used to map the user code to the required Time
Zones. The actual Time Zone parameters are defined at addresses P681E - P704E.
A single value from 0-8 must be assigned to each user code. Time Zone zero (0) is fixed as 24 hour seven day
access and is the default time zone for all 24 user codes.
P73E
TZ E
Where TZ represents the Time Zone from 0-8 valid for User Code #1 (Fixed as TZ-0)
P74E
TZ E
Where TZ represents the Time Zone from 0-8 valid for User Code #2
P96E
TZ E
Where TZ represents the Time Zone from 0-8 valid for User Code #24
NOTE: More than one Time Zone may be assigned to each user allowing different time based controls for
INSTALLER CODE - P99E
This code is used to enter full Installer Program mode (Program light flashing) from Client Program mode (Program
light steady) The default installer code is 000000. To change this code enter your new installer code at the P99E
address. The new code will be flashed back to you automatically. Like User codes, the Program code may vary
from 3-6 digits in length
P100E Option 8
different days of the week etc.
If this option is on (Led 8 on) then the installer code can access installer mode directly
without needing to enter via client program mode.(All areas must be unset and not in
monitor mode).