11.28 DR 38 Process state extended

11.28
DR 38 Process state extended
The data record contains scale-specific parameters.
Procedure
● Read data record DR 38
● Display/analyze the required tags
Table 11- 28 Assignment of data record 38
Variable
Data record number
Length
Application
Version identifier
Counter zeroing
Counter initial zero calibration
Counter span calibration
Drag indicator (belt load)
Reserve
Current initial zero offset
(belt load)
Current initial zero offset
(in % of nominal load)
Reserve
Reserve
Reserve
Reserve
Reserve
168
Note
Contains no. of data rec-
ord
Data record length infor-
mation
Information about which
application the data record
belongs to
Information about current
data record version
Number of implemented
zeroing procedures, re-
cording of manual and
automatic zeroing proce-
dures (is reset when load-
ing the factory settings)
Number of implemented
initial zero calibration pro-
cedures (is reset when
loading the factory set-
tings)
Number of implemented
span calibration proce-
dures (is reset when load-
ing the factory settings)
Maximum belt load that
has occurred
Current deviation from
original zero (when load-
ed)
Current deviation from
original zero (in % of nom-
inal load)
3xLONG
Type
L
Rw Default
USHORT
2
r
38
USHORT
2
r
64
USHORT
2
r
104
USHORT
2
r
1
ULONG
4
r
0
ULONG
4
r
0
ULONG
4
r
0
FLOAT
4
r
0
LONG
4
r
0
FLOAT
4
r
0
FLOAT
4
r
0
FLOAT
4
r
0
LONG
4
r
0
LONG
4
r
0
LONG
4
r
0
LONG
12
0
Min.
Max.
Register
-
-
4500
-
-
4501
-
-
4502
1
65635
4503
4504
4506
4508
4510
4512
4514
4516
4518
4520
4522
4524
4526
SIWAREX WT241