DR 19 External speed

If the SIWAREX module is not to determine the belt speed because the current speed is
available externally, e.g. in a controller, it can be passed on to the SIWAREX via DR 19. The
current material flow rate can then be calculated.
Procedure
● Enter a value in data record DR 19
● Transfer the data record to the scale
Table 11- 20 Assignment of data record 19
Variable
Note
Data record num-
Contains no. of data record
ber
Length
Data record length information
Application
Information about which application the
data record belongs to
Version identifier
Information about current data record
version
External speed
The externally determined speed can be
value
sent to the scale.
Reserve 1
Reserve
Reserve 2
Reserve
SIWAREX WT241
Manual, 05/2015, A5E36046748Aa
Type
L Rw
Default Min.
USHORT
2 r
19
USHORT
2 r
16
USHORT
2 r
104
USHORT
2 r
1
FLOAT
4 rw
0
SHORT
2 rw
0
USHORT
2 rw
0
Communication
11.20 DR 19 External speed
Max.
Regis-
ter
-
-
1602
-
-
1603
-
-
1604
1
65635
1605
-
-
1606
0
-
1608
0
-
1609
149