Dr 16 Simulation (Belt Speed And Belt Load) - Siemens SIWAREX WT241 Manual

Electronic
Table of Contents

Advertisement

11.17

DR 16 Simulation (belt speed and belt load)

The belt load and belt speed can be simulated using an input via data record DR 16. The
SIWAREX module must first be released for simulation mode in DR 3 and then activated
with command 3 or 5 or deactivated with command 4 or 6.
Procedure
● Release simulation mode in DR 3
● Send command no. 3 and/or 5 to the SIWAREX module
● Enter the belt load and/or speed to be simulated
● Transfer the data record to the SIWAREX module
Table 11- 17 Assignment of data record 16
Variable
Note
Data record
Contains no. of data record
number
Length
Data record length infor-
mation
Application
Information about which ap-
plication the data record
belongs to
Version
Information about current
identifier
data record version
Value for belt
load simula-
tion
(Page 145)
Value for belt
speed simu-
lation
(Page 145)
Reserve
Reserve
Reserve
11.17.1
Value for belt load simulation
Only use values for the belt load which are within the measuring range of the scale. The
word "TEST" is displayed on the main display during simulation and a status bit is set.
11.17.2
Value for belt speed simulation
Only use values for simulation of the belt speed which are within the speed range of the belt.
The word "TEST" is displayed on the main display during simulation and a status bit is set.
SIWAREX WT241
Manual, 05/2015, A5E36046748Aa
11.17 DR 16 Simulation (belt speed and belt load)
Type
L
Rw
USHORT
2
r
USHORT
2
r
USHORT
2
r
USHORT
2
r
FLOAT
4
rw
SHORT
2
rw
USHORT
2
rw
USHORT
2
rw
Communication
Default
Min.
Max.
16
-
-
20
-
-
104
-
-
1
1
65635
0
-
-
0
0
-
0
0
-
0
0
-
Register
1578
1579
1580
1581
1582
1584
1586
1587
145