Load simulation active
Stop watch active
Clock error
Trace active
Error on digital input
Pulse signal for remote
totalizer
Scale calibrated
Service mode active
Calibration procedure acti-
ve
Write protection active
Error analog output
Warm up time
Start up
System fault
2.2.4 Scale status 5 of 5
Digits (unfiltered)
Digits (filtered)
Pulses per belt revolution
Pulses / s
No. of zero calibrations
No. of span calibrations
SIWAREX WT241
Manual, 05/2015, A5E36046748A
Set in case belt load simulation mode is active
Set in case stop watch has been started and is running e.g by
calibration
Set in case RTC buffer was cancelled. Will be reset after setting
the time.
Set in case trace is running
Set in case an error occured due to a command set through
digital input.
Set in case a digital output has been defined as pulse signal for
external totalizer and is running.
Please refer to menu 1.5.3 "Remote totalizer pulse signal"
Calibration of load and speed has been performed.
Service mode is activated.
Set in case calibration has been started.
Write protection is active
Analogue output is disturbed
Warm up time after power on is running
Weighing electronic is starting up or restoring of recovery point
was done. Will be reset after 5 seconds.
System is disturbed
Further process values
The unfiltered digit value (measurement of weight) is the internal
measured value immediately before filtering.
The filtered digit value (measurement of weight) is the internal
measured value immediately after filtering.
Number of sensor pulses per belt revolution.
Current integer value of impulses per second.
Number of performed zero calibrations. Will be reset with restor-
ing the default values.
Number of performed span calibrations. Will be reset with restor-
ing the default values.
Scale parameters and functions of the belt scale
8.10 Menu 2.2 Scale status