11.26 DR 33 Totalizers

11.26
DR 33 Totalizers
Data record DR 33 contains the actual values of the totalizers.
Totalizing becomes active when the minimum belt load for the totalizer (parameter in DR6)
has been exceeded. Command 652 can be used to stop all totalizers except S6. Command
651 starts totalizing again.
Table 11- 26 Assignment of data record 33
Variable
Note
Data record num-
Contains no. of data record
ber
Length
Data record length information
Application
Information about which application the
data record belongs to
Version identifier
Information about current data record
version
Current master
Master totalizer (S1) since commissioning
totalizer (S1)
of the scale
(Page 164)
Current main total-

Current main totalizer (S2)

izer (S2)
(Page 164)
Reserve
-
Totalizer 3 (S3),
Totalizer S3
totalizer 4 (S4),
Totalizer S4
totalizer 5 (S5)
Totalizer S5
(Page 165)
Totalizer 6 (S6)
Totalizer S6
(Page 165)
Reserve
-
11.26.1

Current master totalizer (S1)

This totalizer contains the total of conveyed material since commissioning of the scale. The
master totalizer can only be reset by loading the factory settings.
11.26.2
Current main totalizer (S2)
The totalizer contains the quantity of material transported since the last memory reset. The
operating total must be logged in the case of trade scales requiring verification (available
soon). You can reset the total using command 670.
164
Type
L
Rw
Default
USHORT
2
r
33
USHORT
2
r
44
USHORT
2
r
104
USHORT
2
r
1
DOUBLE
8
r
0
FLOAT
4
r
0
FLOAT
4
r
0
FLOAT
4
r
0
FLOAT
4
r
0
FLOAT
4
r
0
FLOAT
4
r
0
FLOAT
4
r
0
Min.
Max.
Regis-
ter
-
3514
-
3515
-
3516
3517
3518
3522
3524
3526
3528
3530
3532
3534
SIWAREX WT241
Manual, 05/2015, A5E36046748A