Technical specifications
12.1 Technical specifications
RS485 interface
Table 12- 7
Standard
Baud rate
Data bits
Parity
Stop bits
Terminating resistors (can be activated)
Electrical isolation
Transfer protocol
Cable length
Ethernet
Table 12- 8
Standard
Transmission rate
Electrical isolation
Transfer protocol
Autonegotiation
Auto MDI-X
Cable lengths
Dimensions and weights
Table 12- 9
Dimensions W x H x D
Weight
174
Technical specifications: RS485 interface
Technical specifications: Ethernet
Cat-5e UTP cable
(unshielded)
Cat-5e SF/UTP
cable (shielded)
Technical specifications:
EIA-485
up to 115 kbps*
7 or 8
even | odd | none
1 or 2
390 Ω / 220 Ω / 390 Ω
500 V AC
ASCII for remote display from Siebert and Mod-
bus RTU)
≤ 115 kbps max. 1 000 m
(fieldbus cable 2-wire, shielded, e.g. 6XV1830-
0EH10)
IEEE 802.3
10/100 Mbps (determined automatically)
1 500 V AC
TCP/IP, Modbus TCP
(see /1/)
yes
yes
max. 50 m
max. 100 m
264 x 185 x 97 mm
4 kg