Siemens SIWAREX WT241 Manual page 127

Electronic
Table of Contents

Advertisement

Variable
Note
Response
0: Switch off
of analog
1: retain function
output to
2: Output configured output value
faults or
3: Output maximum value (24 mA,
SIMATIC
NAMUR)
STOP
(Page 130)
Start value
Value at which 0 ...4 mA is to be output
for the
analog
output
(Page 131)
End value
Value at which 20 mA is to be output
for the
analog
output
(Page 131)
Output
Value to be output when the OutDis
value fol-
signal is enabled (in mA)
lowing fault
or SIMATIC
STOP
(Page 131)
Trace re-
1: 10 ms
cording
10: 100 ms
cycle
100: 1 s
(Page 131)
1 000: 10 s
Trace stor-
0: Trace recording runs as a circular
age method
buffer
(Page 131)
1: Trace is stopped when the trace
memory is full
Bit 1
Reserve
Bit 2
Reserve
Bit 3
Reserve
Bit 4
Reserve
Bit 5
Reserve
Bit 6
Reserve
Bit 7
Reserve
Bit 8
Reserve
Bit 9
Reserve
Bit 10
Reserve
Bit 11
Reserve
Bit 12
Reserve
Bit 13
Reserve
Bit 14
Reserve
Bit 15
Reserve
SIWAREX WT241
Manual, 05/2015, A5E36046748Aa
Type
L
Rw
Default
USHORT
2
rw
0
FLOAT
4
rw
0
FLOAT
4
rw
0
FLOAT
4
rw
0
USHORT
2
rw
1
BIT
0
rw
0
BIT
0
rw
0
BIT
0
rw
0
BIT
0
rw
0
BIT
0
rw
0
BIT
0
rw
0
BIT
0
rw
0
BIT
1
rw
0
BIT
0
rw
0
BIT
0
rw
0
BIT
0
rw
0
BIT
0
rw
0
BIT
0
rw
0
BIT
0
rw
0
BIT
0
rw
0
BIT
1
rw
0
Communication
11.10 DR 7 Process interfaces
Min.
Max.
Register
0
3
1326
maxi-
maxi-
1327
mum
mum
weigh-
weighing
ing
range
range
maxi-
maxi-
1329
mum
mum
weigh-
weighing
ing
range
range
0
24
1331
1
1000
1333
0
1
1334.16
0
1
1334.15
0
1
1334.14
0
1
1334.13
0
1
1334.12
0
1
1334.11
0
1
1334.10
0
1
1334.9
0
1
1334.8
0
1
1334.7
0
1
1334.6
0
1
1334.5
0
1
1334.4
0
1
1334.3
0
1
1334.2
0
1
1334.1
127