Load Per Pulse - Siemens SIWAREX WT241 Manual

Electronic
Table of Contents

Advertisement

Communication
11.10 DR 7 Process interfaces
Value
0
1
11.10.14

Load per pulse

By parameterizing the corresponding digital output you can use one of the digital outputs as
a pulse sensor/quantity (see Assignment digital output DQ 0, 1, 2, 3 (Page 128)).
In addition you must specify a load per pulse and a pulse duration for the signal. If the
material flow rate is displayed e.g. in t/h, you must specify the quantity per pulse in t, or with
kg/h in kg. The pulse duration is defined in ms.
Make sure when setting the parameters that you only enter plausible combinations → pulse
duration > (amount per pulse / material flow rate)
132
Response
Trace recording runs as circulating memory
Trace is stopped when the trace memory is full
SIWAREX WT241