Dr 13 Rs485 Parameters - Siemens SIWAREX WT241 Manual

Electronic
Table of Contents

Advertisement

Communication

11.15 DR 13 RS485 parameters

11.15
DR 13 RS485 parameters
The parameters which define the response of the RS485 interface are specified in data
record DR 13. If the interface is not used, the default values can be retained.
Procedure
● Check the parameters and modify them as required
● Transfer the data record to the scale
Table 11- 15 Assignment of data record 13
Variable
Note
Data record
Contains
number
no. of data
record
Length
Data record
length in-
formation
Application
Information
about which
application
the data
record
belongs to
Version
Information
identifier
about cur-
rent data
record
version
RS485
0: No pro-
protocol
tocol
(Page 141)
1:
MODBUS
RTU
RS485
2: 9
baud rate
600 bps
(Page 142)
3: 19
200 bps
4: 38
400 bps
5: 57
600 bps
6:115 000 b
ps
RS485
Character
character
parity
parity
0: Even
(Page 142)
1: Odd
140
Type
L
USHORT
2
USHORT
2
USHORT
2
USHORT
2
USHORT
2
USHORT
2
BIT
0
Rw
Default
r
13
r
24
r
104
r
1
rw
1
rw
3
rw
0
Min.
Max.
-
-
-
-
-
-
1
65635
0
2
0
6
0
1
SIWAREX WT241
Manual, 05/2015, A5E36046748A
Register
1558
1559
1560
1561
1562
1563
1564.16

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents