11.13

DR 10 load cell parameters

The parameters of the analog load cells must be checked prior to the automatic calibration
and modified if necessary. Only the parameters identified by bold font and asterisk (*) need
be entered.
Procedure
● Check the parameters and modify them as required
● Transfer the data record to the scale
● Calibrate the scale
Table 11- 13 Assignment of data record 10
Variable
Note
Data record
Contains no. of data record
number
Length
Data record length information USHORT
Application
Information about which appli-
cation the DR belongs to
Version iden-
Information about current data
tifier
record version
Number of
Number of analog load cells
load cells
(Page 135)
1)
50/60 Hz
50/60 Hz toggling
toggling
(Page 136)
Reserve 1
Reserve
Load cell
Characteristic value of the
characteristic
load cell (n) [mV/V], the mean
value
value is used if there is more
(Page 136)
than one cell.
1)
Rated load of
Rated load of a load cell
a load cell
(Page 136)
1)
Reserve
Reserve
Reserve
Reserve
Reserve 2
Reserve
Reserve 3
Reserve
Reserve 4
Reserve
Parameter for calculation of calibration points with theoretical calibration
1)
11.13.1

Number of load cells

The number of load cells is required for automatic calibration.
SIWAREX WT241
Manual, 05/2015, A5E36046748Aa
Type
L
Rw
USHORT
2
r
2
r
USHORT
2
r
USHORT
2
r
USHORT
2
rw
USHORT
2
rw
USHORT
2
rw
FLOAT
4
rw
FLOAT
4
rw
FLOAT
4
rw
FLOAT
4
rw
SHORT
2
rw
USHORT
2
rw
FLOAT
4
rw
11.13 DR 10 load cell parameters
De-
Min.
Max.
fault
10
-
-
38
-
-
104
-
-
1
1
65635
1
1
6
0
0
1
0
0
0
2
> 0.1
10
60
-
-
0
-
-
0
-
-
0
-
-
0
-
-
0
-
-
Communication
Register
1400
1401
1402
1403
1404
1405
1406
1407
1409
1411
1413
1415
1416
1417